134 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Managing your IronStack
5
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 31.5 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 32.0 deg-C
Boot Prom MAC: 0012.f2db.e500
Syntax: show chassis
Table 26 describes the fields displayed in this output example.
Displaying stack module information
The show module command displays information about the stack unit modules. Output resembles
the following.
PowerConnect(config)# show module
Module Status Ports Starting MAC
S1:M1 FCX-24G 24-port Management Module OK 24 00e0.5201.4000
S1:M2 FCX-2XGC 2-port 16G Module (2-CX4) OK 2 00e0.5201.4018
S1:M3 FCX-1XG 1-port 16G Module (1-XFP) OK 1 00e0.5201.401a
S3:M1 FCX-48G 48-port Management Module OK 48 001b.ed5e.c480
S3:M2 FCX-1XG 1-port 16G Module (1-XFP) OK 1 001b.ed5e.c4b0
S3:M3 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 001b.ed5e.c4b1
S4:M1 FCX-48G 48-port Management Module OK 48 001b.ed5e.ac00
S4:M2 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 001b.ed5e.ac30
S4:M3 FCX-1XG 1-port 16G Module (1-XFP) OK 1 001b.ed5e.ac31
S5:M1 FCX-24G 24-port Management Module OK 24 001b.ed5d.a180
S5:M2 FCX-1XG 1-port 16G Module (1-XFP) OK 1 001b.ed5d.a198
S5:M3 FCX-1XG 1-port 16G Module (1-XFP) OK 1 001b.ed5d.a199
S5:M4 FCX-1XG 1-port 16G Module (1-XFP) OK 1 001b.ed5d.a19a
S6:M1 FCX-24G 24-port Management Module OK 24 00e0.5200.3000
S6:M2 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 00e0.5200.3018
S6:M3 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 00e0.5200.3019
S7:M1 FCX-48G 48-port Management Module OK 48 00e0.4444.0000
S7:M2 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 00e0.4444.0030
S7:M3 FCX-1XGC 1-port 16G Module (1-CX4) OK 1 00e0.4444.0031
S8:M1 FCX-48G 48-port Management Module OK 48 0012.f2eb.d540
TABLE 26 Field definitions for the show chassis command
This field... Describes...
Power Supply 1 The status of the primary power supply.
Power Supply 2 The status of the secondary power supply, if present.
Fan 1 and Fan 2 The status of the cooling fans
Exhaust Side Temperature
Readings
From the air exhaust side of the chassis, the current temperature reading, the
warning level temperature setting, and the shutdown level temperature
setting.
Intake Side Temperature Reading The current temperature reading from the air intake side of the chassis.
Boot Prom MAC The MAC address of the boot prom
Management MAC For the Active Controller only, the management MAC address