Dell FCX624-I Laptop User Manual


  Open as PDF
of 1494
 
PowerConnect B-Series FCX Configuration Guide 515
53-1002266-01
Displaying GVRP information
14
CPU utilization statistics
GVRP diagnostic information
Displaying GVRP configuration information
To display GVRP configuration information, enter a command such as the following.
Syntax: show gvrp [ethernet <port>]
Specify the <port> variable in the following formats:
PowerConnect B-Series FCX stackable switches – <stack-unit/slotnum/portnum>
This display shows the following information.
TABLE 82 CLI display of summary GVRP information
This field... Displays...
Protocol state The state of GVRP. The display shows one of the following:
GVRP is disabled on the system
GVRP is enabled on the system
GVRP BASE VLAN ID The ID of the base VLAN used by GVRP.
GVRP MAX Leaveall Timer The maximum number of ms to which you can set the Leaveall timer.
NOTE: To change the maximum value, refer to “Increasing the maximum
configurable value of the Leaveall timer” on page 510.
PowerConnect#show gvrp
GVRP is enabled on the system
GVRP BASE VLAN ID : 4093
GVRP MAX Leaveall Timer : 300000 ms
GVRP Join Timer : 200 ms
GVRP Leave Timer : 600 ms
GVRP Leave-all Timer : 10000 ms
===========================================================================
Configuration that is being used:
block-learning ethe 1/3
block-applicant ethe 2/7 ethe 2/11
enable ethe 1/1 to 1/7 ethe 2/1 ethe 2/7 ethe 2/11
===========================================================================
Spanning Tree: SINGLE SPANNING TREE
Dropped Packets Count: 0
===========================================================================
Number of VLANs in the GVRP Database: 15
Maximum Number of VLANs that can be present: 4095
===========================================================================