PowerConnect B-Series FCX Configuration Guide 1391
53-1002266-01
Syslog messages
41
To display TCP or UDP port numbers instead of their names, enter the following command.
PowerConnect(config)#ip show-service-number-in-log
Syntax: [no] ip show-service-number-in-log
Retaining Syslog messages after a soft reboot
You can configure the device to save the System log (Syslog) after a soft reboot (reload command).
Configuration considerations
If the Syslog buffer size was set to a different value using the CLI command logging buffered,
the System log will be cleared after a soft reboot, even when this feature (logging persistence)
is in effect. This will occur only with a soft reboot immediately following a Syslog buffer size
change. A soft reboot by itself will not clear the System log. To prevent the system from clearing
the System log, leave the number of entries allowed in the Syslog buffer unchanged.
This feature does not save Syslog messages after a hard reboot. When the Dell PowerConnect
device is power-cycled, the Syslog messages are cleared.
To configure the device to save the System log messages after a soft reboot, enter the following
command.
PowerConnect(config)#logging persistence
Syntax: [no] logging persistence
Enter no logging persistence to disable this feature after it has been enabled.
Clearing the Syslog messages from the local buffer
To clear the Syslog messages stored in the local buffer of the Dell PowerConnect device, enter the
following command.
PowerConnect#clear logging
Syntax: clear logging
Syslog messages
Table 239 lists all of the Syslog messages. Note that some of the messages apply only to Layer 3
Switches. The messages are listed by message level, in the following order, then by message type:
Emergencies (none)
Alerts
Critical
Errors
Warnings
Notifications
Informational
Debugging