Dell FCX624-S Laptop User Manual


  Open as PDF
of 1494
 
1394 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Syslog messages
41
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config read
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration read failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI config write
failure. Module will be deleted.
The module encountered an unrecoverable
hardware configuration write failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI device
validation failure. Module will be deleted.
The module encountered an unrecoverable
(hardware) device validation failure. The
module will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
read failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory read failure. The module
will be disabled or powered down.
Alert System: Module in slot <slot-num>
encountered unrecoverable PCI memory
write failure. Module will be deleted.
The module encountered an unrecoverable
hardware memory write failure. The module
will be disabled or powered down.
Alert System: Temperature is over shutdown level,
system is going to be reset in <num>
seconds
The chassis temperature has risen above
shutdown level. The system will be shut
down in the amount of time indicated.
Alert Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
Indicates an over temperature condition on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
Critical Authentication shut down <portnum> due to
DOS attack
Denial of Service (DoS) attack protection
was enabled for multi-device port
authentication on the specified <portnum>,
and the per-second rate of RADIUS
authentication attempts for the port
exceeded the configured limit. The Dell
PowerConnect device considers this to be a
DoS attack and disables the port.
Debug BGP4: Not enough memory available to run
BGP4
The device could not start the BGP4 routing
protocol because there is not enough
memory available.
Debug DOT1X: Not enough memory There is not enough system memory for
802.1X authentication to take place.
Contact Dell Technical Support.
Error No of prefixes received from BGP peer
<ip-addr> exceeds maximum
prefix-limit...shutdown
The Layer 3 Switch has received more than
the specified maximum number of prefixes
from the neighbor, and the Layer 3 Switch is
therefore shutting down its BGP4 session
with the neighbor.
Informational IPv6: IPv6 protocol disabled on the device
from <session-id>
IPv6 protocol was disabled on the device
during the specified session.
TABLE 239 Syslog messages (Continued)
Message level Message Explanation