114 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Building an IronStack
5
If you enter an incorrect stack port number, you will get an error similar to the following.
PowerConnectconfig-unit-3)# stack-port 3/4/1
Error! port 3/4/1 is invalid
PowerConnect(config-unit-3)# stack-port 3/2/1
To return both ports to stacking status, enter the no stack-port command on the single stacking
port. This converts both ports to stacking ports. By default, if both ports are stacking ports, they are
displayed by the system only when stacking is enabled. If only one port is configured as a stacking
port, the system always displays this port.
Using secure-setup to build an FCX IronStack
You can use the secure-setup utility to build an PowerConnect B-Series FCX IronStack by
performing the following steps.
1. When you have designated the desired stacking ports and connected your PowerConnect
B-Series FCX units together, on stack unit 1, enter stack enable and stack secure-setup, as
shown.
PowerConnect# stack enable
PowerConnect# stack secure-setup
PowerConnect# Discovering the stack topology...
Available UPSTREAM units
Hop(s) Id Type Mac Address
1 new FCX648 0012.f2d6.0511
2 new FCX624 0200.9999.0000
Enter the number of the desired UPSTREAM units (0-2)[0]: 2
Selected Topology:
Active Id Type Mac Address
1 FCX624 001b.f2e5.0100
Selected UPSTREAM units
Hop(s) Id Type Mac Address
1 2 FCX648 0012.f2d6.0511
2 3 FCX624 0200.9999.0000
Do you accept the unit ids (y/n)?: y
PowerConnect# Election, was alone --> active, assigned-ID=1, total 3 units, my
priority=128
Election, was active, no role change, assigned-ID=1, total 3 units, my
priority=128
reset unit 2: diff bootup id=1
reset unit 3: diff bootup id=1
Election, was alone --> active, assigned-ID=1, total 3 units, my priority=128
Detect stack member 2 capable
Detect stack unit 2 has different startup config flash, will synchronize it
Detect stack unit 3 has different startup config flash, will synchronize it
Done hot swap: Set stack unit 3 to Ready
Done hot swap: Set stack unit 2 to Ready
Synchronize startup config to stack unit 2
Flash Memory Write (8192 bytes per dot).Synchronize startup config to stack
unit 3
Flash Memory Write (8192 bytes per dot). Stack unit 2 Power supply 1 with 4
10000 mwatts capacity is up
Stack unit 2 Power supply 2 is down