Dell FCX624-S Laptop User Manual


  Open as PDF
of 1494
 
192 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Digital optical monitoring
6
Digital optical monitoring
You can configure your Brocade device to monitor optical transceivers in the system, either globally
or by specified ports. When this feature is enabled, the system will monitor the temperature and
signal power levels for the optical transceivers in the specified ports. Console messages and
Syslog messages are sent when optical operating conditions fall below or rise above the XFP or SFP
manufacturer recommended thresholds.
Table 42 on page 191 specifies which Dell-qualified media types support digital optical monitoring.
Configuration limitations
A Dell chassis device can monitor a maximum of 24 SFPs and 12 XFPs.
Enabling digital optical monitoring
To enable optical monitoring on all Dell-qualified optics installed in the device, use the following
command.
PowerConnect(config)#optical-monitor
To enable optical monitoring on a specific port, use the following command.
PowerConnect(config)#interface ethernet 1/1
PowerConnect(config-if-e10000-1/1)#optical-monitor
To enable optical monitoring on a range of ports, use the following command.
PowerConnect(config)#interface ethernet 1/1 to 1/2
PowerConnect(config-mif-e10000-1/1-1/2)#optical-monitor
Syntax: [no] optical-monitor
10G-XFP-SR FTLX8511D3-F1
AFBR-720XPDZ-FD1
PLRXXL-SC-S43-59
TRF2001EN-GA250
10GBase-SR XFP YY0VX Yes
10G-SFPP-SR FTLX8571D3BNL-B2
AFBR-703ASDZ-BR2
10GE SR SFP+ DR7C1 Yes
10G-SFPP-LR FTLX1471D3BNL-B2
AFCT-701ASDZ-BR2
10GE LR SFP+ 6D0R3 Yes
XDL-10G-SFPP-TWX-0
101
579890006
2GSPWWA-BEB-EN
DIRECT ATTACHED SFPP
COPPER,1M,1-PACK
60HMX No
XDL-10G-SFPP-TWX-0
301
579890004
2GSPWWB-BFB-EN
DIRECT ATTACHED SFPP
COPPER,3M,1-PACK
GPPHR No
XDL-10G-SFPP-TWX-0
501
579890001
2GSPWWC-BGB-EN
DIRECT ATTACHED SFPP
COPPER,5M,1-PACK
D93W5 No
TABLE 42 Supported fiber optic transceivers (Continued)
Label Manufacturing part number Type Dell part number Supports Digital
Optical Monitoring?