Dell HHB Laptop User Manual


 
Error Code Message Information
a platform event (such as power down, cycle, interrupt, and send
alert).
Action Review platform event configuration.
SEL1211
Message The time-stamp clock could not be synchronized.
Details The time stamp on system event log events may not correlate to the
system time.
Action Cycle system input power. If problem persists, contact support.
SEL1300
Message No bootable media found.
Details System setup displays the system boot order. The local video screen
may also show additional information. (IPMI sensor type code 1eh -
offset 00h).
Action Check system boot settings. Check if mass storage controller
configuration settings are applicable.
SEL1302
Message Non-bootable diskette detected.
Details The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.
Action Replace diskette with a bootable disk.
SEL1304
Message The PXE server not found.
Details PXE is one way to boot a system from the network.
Action Check the network and PXE server configuration.
SEL1306
Message Invalid boot sector found.
Details The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.
Action Replace diskette with a bootable disk.
SEL1308
Message A time-out occurred while waiting for user to select a boot source.
Details The system has failed to boot to an operating system and needs the
user to select a boot source.
Action Select boot source within the time allowed.
SEL1501
Message Chassis management controller (CMC) redundancy is lost.
119