Error Code Message Information
Action Check the system operating environment and review event log for fan
failures.
TMP0115
Message The <
name
> temperature is greater than the upper critical threshold.
LCD Message The <
name
> temperature is outside of range. Check Fans
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0116
Message The <
name
> temperature is outside of range.
LCD Message The <
name
> temperature is outside of range. Check Fans
Action Check the system operating environment and review event log for fan
failures.
TMP0118
Message The system inlet temperature is less than the lower warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0119
Message The system inlet temperature is less than the lower critical threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0120
Message The system inlet temperature is greater than the upper warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0121
Message The system inlet temperature is greater than the upper critical
threshold.
124