Dell HHB Laptop User Manual


 
Error Code Message Information
Action Review system logs for memory exceptions. reinstall memory at
location <
location
>
MEM1214
Message Memory redundancy is degraded.
Details The memory may not be seated correctly, misconfigured, or has
failed.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM7002
Message A hardware mismatch detected for memory riser.
LCD Message Memory riser mismatch detected. Check memory riser.
Details Memory riser is installed incorrectly, or failed.
Action Check that the memory riser is installed correctly. If the issue
persists, see Getting Help.
MEM8000
Message Correctable memory error logging disabled for a memory device at
location <
location
>.
LCD Message SBE log disabled on <
location
>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. reinstall memory at
location <
location
>.
OSE0000
Message A critical stop occurred during OS load.
Details The system halted due to an exception during operating system load
or operating system initialization.
Action Review operating system logs and system video for additional
information.
OSE0001
Message A runtime critical stop occurred.
Details The system halted due to an exception while the operating system
was running. This is a kernel panic or bug check event.
Action Review operating system logs and system video for additional
information.
OSE0004
Message A soft shut-down initiated by platform event filter.
Details A separate exception or status condition shutdown the operating
system. (IPMI sensor type 20h - offset 04h).
95