Delta Electronics DVP06AD-S Network Card User Manual


 
Warning
Please read this instruction carefully before use.
DO NOT tough any terminal when the power is switched on. Switch off the power before wiring.
DVP06AD-S is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust,
humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device
(e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may occur.
DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all
the wiring again before switching on the power.
DO NOT touch any internal circuit in 1 minute after the power is switched off.
Make sure the groud terminal is correctly grounded in order to prevent electromagnetic interference.
Introduction
Model Explanation & Peripherals
Thank you for choosing Delta DVP series. The analog signal input module DVP06AD-S is able to receive 6
points of external analog signal inputs (both in voltage and current) and convert the signals into 14-bit
digital ones. It is able to read and write the data in the module through FROM/TO instructions given by the
program of DVP-PLC SS/SA/SX/SC/SV series MPU. There are 49 16-bit control registers in the module.
The user can select voltage or current output by wiring. Range of voltage output: 10V DC (resolution:
1.25mV). Range of current output: 20mA (resolution: 5µA).
Product Profile & Outline
1.
POWER, ERROR, A/D indicator
2.
DIN rail clip
3.
Terminals
4.
Extension unit/module mounting hole
5.
Nameplate
6.
Extension unit/module connection port
7.
Extension unit/module fixing clip
8.
DIN rail (35mm)
9.
RS-485 communication port
10.
Extension unit/module fixing notch
11.
Power input port
3.0090.00
3.00
25.20
60.00 3.40
1
2
12
3
4
6
8
2
5
7
10
9
11
60.00
3.00
Unit: mm
12.
Extension unit/module connection port
External Wiring
CH1
104.7K
250
-10V~+10V
V+
I+
COM
CH1
100K
CH6
104.7K
250
-20mA~+20mA
V+
I+
COM
CH6
100K
*4
*2
AG
AG
24+
24-
100 or less)
(
DC/DC
+15V
-15V
AG
*3
Voltage input
Shielding cabl e*1
Shielding cabl e*1
Current input
System grounding
Earth
Connected to
terminal
of the power module
Coverter
DVP06AD-S
COM
V+
I+
COM
V+
I+
COM
V+
I+
COM
V+
I+
COM
V+
I+
COM
V+
I+
ENGLISH
*1: When performing analog input, p
lease isolate other power wirings.
*2: When connecting to current signals, please make sure to short-circuit “V+” and “I+” terminals.
*3: Please connect the terminal on both the power module and DVP06AD-S to the system earth point and ground the
system contact or connect it to the cover of power distribution cabinet.
*4: If the ripples at the loaded input terminal are too significant that causes noise interference on the wiring, connect the
wiring to 0.1 ~ 0.47µF 25V capacitor.
Note: DO NOT wire empty terminals
Specifications
Functions
Analog/Digital
(6A/D) module
Voltage input Current input
Power supply voltage 24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%)
Analog input channel 6 channels/module
Range of analog input ±10V ±20mA
Range of digital
conversion
±8,000 ±4,000
Resolution 14 bits (1
LSB
=1.25mV) 13 bits (1
LSB
=5µA)
Input impedance 200K or more 250
Overall accuracy
±0.5% when in full scale (25°C, 77°F)
±1% when in full scale in the range of 0 ~ 55°C, 32 ~ 131°F
Response time 3ms × the number of channels
Isolation Isolation between digital area and analog area. No isolation among channels.
Range of absolute input ±15V ±32mA
Digital data format 13 significant bits out of 16 bits are available; in 2’s complement.
Average function Yes. Available for setting up in CR#2 ~ CR#7; range: K1 ~ K20.
Self-diagnosis Upper and lower bound detection/channel
Communication mode
(RS-485)
ASCII/RTU mode.
Communication speed: 4,800/9,600/19,200/38,400/57,600/115,200
ASCII data format: 7-bit, even bit, 1 stop bit (7, E, 1)
RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1)
RS-485 cannot be used when connected to PLC MPU in series.
When connected to
DVP-PLC MPU in series
The modules are numbered from 0 to 7 automatically by their distance from MPU.
Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/O
points.
Others
Power supply
Max. rated power
consumption
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%), 2W, supplied by external power.
Environment
Operation/storage
Operation: 0°C ~ 55°C (temperature); 50 ~ 95% (humidity); pollution degree 2.
Storage: -25°C ~70°C (temperature); 5 ~ 95% (humidity).
Vibration/shock
immunity
International standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC
68-2-27 (TEST Ea)
Installation & Wiring
Mounting Arrangements and Wiring Notes
Control Registers
CR
#
RS-485
parameter
address
Latched
Register content b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
#0 H’4000
R Model name
Set by the system. Data length: 8 bits (b7 ~ b0).
DVP06AD-S model code=H’C8.
Reserved CH6 CH5 CH4 CH3 CH2 CH1
#1 H’4001
R/W Input mode setting
Input mode: Default=H’0000.
Mode 0: Voltage input (-10V ~ +10V)
Mode 1: Voltage input (-5V ~ +10V)
Mode 2: Current input (-12mA ~ +20mA)
Mode 3: Current input (-20mA ~ +20mA)
CR#1: The working mode of the 6 channels in the analog input module. There are 4 modes for each channel which can
be set up separately. For example, if the user needs to set up CH1: mode 0 (b2 ~ b0=00) and CH2: mode 1 (b5 ~ b3=01),
CH3: mode 2 (b8 ~ b6=10), CH4: mode 3 (b11 ~ b9=11), CH5: mode 0 (b11 ~ b9=00), CH6: mode 1 (b11 ~ b9=01), CR#1
has to be set as H’04EA and the higher bits (b12 ~ b15) have to be reserved. Default value=H’0000.
#2
H’4002
R/W
CH2 CH1
#3
H’4003
R/W
CH4 CH3
#4
H’4004
R/W
CH1 ~ CH6
Average times setting
CH6 CH5
CR#2 ~ CR#4: Range of settings in CH1 ~ CH6: K1 ~ K20. The settings of average times of the signals at CH1 ~ CH6.
Range: K1 ~ K20. For example, if the average time at CH1 is to be set as K10 and CH2 as K18, CR#2 has to be set as
H’120A. CR#3 ~ 4 apply the same rule. The default setting of each channel=K10. Default settings of CR#2 ~ CR#4 are all
H’0A0A.
#6
H’4006
R CH1 input average
#7
H’4007
R CH2 input average
#8
H’4008
R CH3 input average
#9
H’4009
R CH4 input average
#10
H’400A
R CH5 input average
#11
H’400B
R CH6 input average
Average of input signals at CH1 ~ CH6
CR#6 ~ CR#11: The average of the signals at CH1~CH6 obtained from the settings in CR#2~CR#4. For example, if the
settings in CR#2~CR#4 is 10, the content in CR#6~CR#11 will be the average of the most recent 10 signals at CH1~CH6.
How to install DIN rail
DVP-PLC can be secured to a cabinet by using the DIN rail of
35mm in height and 7.5mm in depth. When mounting PLC to
DIN rail, be sure to use the end bracket to stop any side-to-side
movement of PLC and reduce the chance of wires being loosen.
A small retaining clip is at the bottom of PLC. To secure PLC to
DIN rail, place the clip onto the rail and gently push it up. To
remove it, pull the retaining clip down and gently remove PLC
from DIN rail, as shown in the figure.
Please install PLC in an
enclosure with sufficient
space around it to allow
heat dissipation as shown
in the figure.
DVP
MP
D
D
DD
D > 50 mm
Wiring
22-16AW G
< 1.5 mm
1. Use 22-16AWG (1.5mm) single or multiple core wire on I/O wiring terminals. The
specification of the terminal is shown in the figure on the left. The PLC terminal
screws shall be tightened to 1.95 kg-cm (1.7 in-lbs).
2. DO NOT place the I/O signal wires and power supply wire in the same wiring duct.
3. Use 60/75 ºC copper wires only.
CR
#
RS-485
parameter
address
Latched
Register content b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
#12
H’400C
R CH1 input present value
#13
H’400D
R CH2 input present value
#14
H’400E
R CH3 input present value
#15
H’400F
R CH4 input present value
#16
H’4010
R CH5 input present value
#17
H’4011
R CH6 input present value
Present value of input signals at CH1 ~ CH6
#18
H’4012
R/W
Adjusted OFFSET value of CH1
#19
H’4013
R/W
Adjusted OFFSET value of
CH2
#20
H’4014
R/W Adjusted OFFSET value of CH3
#21
H’4015
R/W
Adjusted OFFSET value of CH4
#22
H’4016
R/W
Adjusted OFFSET value of CH5
#23
H’4017
R/W
Adjusted OFFSET value of CH6
OFFSET settings at CH1 ~ CH6. Default=K0; Unit: LSB.
When voltage input, range: K-4,000
LSB
~ K4,000
LSB
.
When current input, range: K-4,000
LSB
~ K4,000
LSB
.
Please refer to this instruction
sheet when setting OFFSET and
GAIN.
#24
H’4018
R/W
Adjusted GAIN value of CH1
#25
H’4019
R/W Adjusted GAIN value of CH2
#26
H’401A
R/W Adjusted GAIN value of CH3
#27
H’401B
R/W
Adjusted GAIN value of CH4
#28
H’401C
R/W
Adjusted GAIN value of CH5
#29
H’401D
R/W
Adjusted GAIN value of CH6
GAIN settings at CH1 ~ CH6. Default=K4,000; Unit: LSB.
When voltage input, range: K-3,200
LSB
~ K16,000
LSB
.
When current input, range: K-3,200
LSB
~ K10,400
LSB
.
Please refer to this instruction sheet when setting OFFSET and
GAIN.
CR#18 ~ CR#29: Please note that: GAIN value – OFFSET value=+800
LSB
~ +12,000
LSB
(voltage) or +800
LSB
~ +6,400
LSB
(current) When GAIN – OFFSET is small (steep oblique), the resolution of input signal will be finer and variation on the
digital value will be greater. When GAIN – OFFSET is big (gradual oblique), the resolution of input signal will be rougher
and variation on the digital value will be smaller.
#30
H’401E
R Error status
Register for storing all error status.
See the table of error status for more information.
CR #30: Error status value (see the table below):
Error status Content b15 ~ b8 b7
b6
b5
b4
b3
b2
b1
b0
Abnormal power supply K1 (H’1) 0 0 0 0 0 0 0 1
Incorrect mode setting K4 (H’4) 0 0 0 0 0 1 0 0
Offset/Gain error K8 (H’8) 0 0 0 0 1 0 0 0
Hardware malfunction K16 (H’10) 0 0 0 1 0 0 0 0
Abnormal digital range K32 (H’20) 0 0 1 0 0 0 0 0
Incorrect average times setting K64 (H’40) 0 1 0 0 0 0 0 0
Instruction error K128 (H’80)
Reserved
1 0 0 0 0 0 0 0
Note: Each error status is determined by the corresponding bit (b0 ~ b7) and there may be more than 2 errors
occurring at the same time. 0=normal; 1=error
#31
H’401F
R/W
Communication address setting
For setting RS-485 communication address.
Range: 01 ~ 254. Default=K1.
#32
H’4020
R/W
Communication speed (baud
rate) setting
For setting up RS-485 communication speed: 4,800/ 9,600/
19,200/ 38,400/ 57,600/ 115,200bps. ASCII data format: 7-bit,
even bit, 1 stop bit (7, E, 1). RTU data format: 8-bit, even bit, 1
stop bit (8, E, 1).
b0: 4,800 bps. b1: 9,600 bps (default).
b2: 19,200 bps. b3: 38,400 bps.
b4: 57,600 bps. b5: 115,200 bps.
b6 ~ b13: Reserved.
b14: High/low bit exchange of CRC checksum (only valid in
RTU mode).
b15: Switch between ASCII/RTU mode.
Return to default CH6 CH5 CH4 CH3 CH2 CH1
#33
H’4021
R/W
Return to default setting;
OFFSET/GAIN tuning
authorization
Take the setting of CH1 for example:
1. b0: Switch for upper/lower bound alarm on the input value for
the channel. 0=disabled; 1=enabled (default).
2. b1: OFFSET/GAIN tuning. 0=forbidden; 1=allowed (default).
3. When b12 ~ b15=1, all values in CH1 ~ CH6 will return to
default settings. b12 ~ b15 will return to 0 automatically after
the setting is completed.
CR for input mode, setting of average times, OFFSET value and GAIN value will be reset after returning to default settings.
#34
H’4022
R Firmware version
Displaying the current firmware version in hex, e.g. version
1.00 is indicated as H’0100.
#35 ~ #48
For system use
Symbols: : Latched (when written in through RS-485 communication).
: Non-latched.
R: Able to read data by FROM instruction or RS-485 communication.
W: Able to write data by TO instruction or RS-485 communication.
LSB (Least Significant Bit): 1. For voltage input: 1
LSB
=10V/8,000=1.25mV.
2. For current input: 1
LSB
=20mA/4,000=5µA.
CR#0 ~ CR#34: The corresponding parameter addresses H’4000 ~ H’4022 are for users to read/write data
by RS-485 communication. When using RS-485, the user has to separate the module with MPU first.
a. Function codes: 03’H (read register data); 06’H (write 1 word datum to register); 10’H (write many words
data to register).
b. Latched CR should be written by RS-485 communication to stay latched. CR will not be latched if written
by MPU through TO/DTO instruction.
Adjusting A/D Conversion Curve
Voltage input mode:
CR#1 mode 0: GAIN=5V (4,000
LSB
). OFFSET=0V (0
LSB
).
CR#1 mode 1: GAIN=6V (4,800
LSB
). OFFSET=2V (1,600
LSB
).
GAIN:
The voltage input value when the digital input value=4,000.
Range: -3,200
LSB
~ +16,000
LSB
.
OFFSET:
The voltage output value when the digital input value=0.
Range: -4,000
LSB
~ +4,000
LSB
.
+
0
0
+4 ,
000
-
4,
000
10V
Vol tageinput
-
8,
0
0
0
-6V-10 V
6V5V
2V
0
Mod
e
1
Mo de 0
GAINOFFSE T
d
ig
i
t
a
l
o
ut
p
u
t
GAIN - OFFSET:
Range: +800
LSB
~ +12,000
LSB
.
Current input mode:
CR#1 mode 2: GAIN=20mA (4,000
LSB
). OFFSET=4mA (800
LSB
).
CR#1 mode 3: GAIN=20mA (4,000
LSB
). OFFSET=0mA (0
LSB
).
GAIN:
The current input value when the digital input value=+4,000.
Range: -3,200
LSB
~ +10,400
LSB
.
OFFSET:
The current input value when the digital input value=0.
Range: -4,000
LSB
~ +4,000
LSB
.
+ 4,00 0
current input
-
4,
0
00
-12mA-20mA
4mA
0
Mode
2
Mode 3
OFFSET
20m
A
GAIN
GAIN - OFFSET:
Range: +800
LSB
~ +6,400
LSB
.
The user can adjust the OFFSET/GAIN curves according to the actual needs by changing the OFFSET value
(CR#18 ~ CR#23) and GAIN value (CR#24 ~ CR#29).
(OPEN TYPE) /
( : )
/
DVP DVP06AD-S 6
14 DVP-PLC SS/SA/SX/SC/SV FROM/TO
49 CR (Control Register)
16 bits
±10V DC ( 1.25mV)
±20mA ( 5µA)
1.
2.
DIN
3.
4.
/
5.
6.
/
7.
/
8.
DIN
(35mm)
9.
RS-485
10.
/
11.
3.0090.00
3.00
25.20
60.00
3.40
1
2
12
3
4
6
8
2
5
7
10
9
11
60.00
3.00
mm
12.
/
CH1
104.7K
250
*1
-10V~+10V
V+
I+
CO M
CH1
100K
CH6
104.7K
250
*1
-20mA~+20mA
V+
I+
CO M
CH6
100K
*4
*2
AG
AG
24+
24-
( 100 )
DC /DC
+15 V
-15V
AG
*3
DVP06AD-S
CO M
V+
I+
CO M
V+
I+
CO M
V+
I+
CO M
V+
I+
CO M
V+
I+
CO M
V+
I+
1
2 V+
I+
3 DVP06AD-S
4 0.1 ~ 0.47µF 25V
/
(6A/D)
(Voltage input) (Current input)
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%)
6 /
±10V ±20mA
±8,000 ±4,000
14 bits (1LSB=1.25mV) 13 bits (1LSB=5µA)
200K 250
±0.5% (25°C, 77°F)
±1% (0 ~ 55°C, 32 ~ 131°F)
3ms ×
±15V ±32mA
16 13 bits
(CR#2 ~ CR#7 K1 ~ K20)
/
(RS-485)
ASCII/RTU (4,800/9,600/19,200/38,400/57,600
/115,200) ASCII 7 bits 1 stop bit (7, E, 1) RTU
8 bits 1 stop bit (8, E, 1) PLC
RS-485
DVP-PLC
0 7 8 I/O
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%), 2W,
/
0 C ~ 55 C ( ) 50 ~ 95% ( ) 2
-25C ~ 70 C ( ) 5 ~ 95%
/
IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27
(TEST Ea)