Delta Electronics DVPAEXT01-H Network Card User Manual


 
Warning
Read this instruction sheet carefully before using DVPAEXT01-H.
DVPAEXT01-H is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust,
humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the
device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may
occur.
DVPAEXT01-H (including DVPAEXT1L-H and DVPAEXT1R-H) is used for connecting MPU and extension unit or
among extension units. Use DVPACAB4A09/DVPACAB4A18 to extend the transmission distance between
DVPAEXT1L-H and DVPAEXT1R-H.
Make sure the power of the MPU and extension unit is switched off when wiring and power on MPU and the
extension unit after the installation of DVPAEXT01-H is completed.
Introduction
Thank you for choosing Delta's DVP series accessory. DVPAEXT01-H is a connector for the extension cable
of extension units. The maximum extension distance available is 1.8m. DVPAEXT01-H is only applicable for
the connection between DVP-EH/EH2/PM series MPU and DI/DO, AI/AO extension units and does not
occupy any extension point or module space.
Product Profile & Outline
DVPAEXT1L-H in the left side (prior level) DVPAEXT1R-H in the right side (next level)
1
3
4
3
5
5
2
6
6
1
3
4
6
6
3
3
Unit: mm
1
Upper cover of connection port
4
DIN rail
2
Terminal for extension cable
5
Extension cable
3
DIN rail clip
6
Direct fixing hole
ENGLISH
Specifications
DVPAEXT01-H Model
Item
DVPAEXT1L-H DVPAEXT1R-H
Power supply Supplied by MPU through its internal bus: 5V DC (4.5 VDC ~ 5.5 VDC) (-10% ~ 10%)
Power consumption 0.5W 0.5W
Noise immunity
ESD: 8KV Air Discharge
EFT: Power Line: 2KV
RS: 26MHz ~ 1GHz, 10V/m
Operation/storage
Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), pollution degree 2
Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity)
Shock/vibration
immunity
International standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)
Weigh (g) 100 100
Installation and Wiring
Connect DVPAEXT01-H with modules
Using DVPAEXT01-H to connect DVP-EH/EH2/PM series MPU with DI/DI, AI/AO extension units.
Cable Connection
When installing DVPAEXT1L-H and DVPAEXT1R-H, please use DVPACAB4A09/DVPACAB4A18
connection cable.
25
14
13
1
1
13
14
25
TO DVPAEXT1L-H
25 PIN D-SUB
TO DVPAEXT1R-H
25 PIN D-SUB
25 PIN D-SUB female
DVPAEXT1L-H COM Port
25
1
1
25
25 PIN D-SUB female
DVPAEXT1R-H COM Port
Note: The DVPAEXT01-H package does not contain the connection cables mentioned above. Please purchase the
cables from our distributors.
OPEN TYPE
DVPAEXT01-H DVPAEXT1L-H DVPAEXT1R-H
DVPAEXT1L-H DVPAEXT1R-H DVPACAB4A09/DVPACAB4A18
DVP 1.8
DVP-EH/EH2/PM DI/DO AI/AO
DVPAEXT1L-H DVPAEXT1R-H
1
3
4
3
5
5
2
6
6
1
3
4
6
6
3
3
mm
1
4
DIN
2
5
3
DIN
6