Delta Electronics GEN Network Card User Manual


 
SNAP-IN MOUNTING HIGH PERFOR-
MANCE IEC CONNECTOR FILTERS
2-7
SERIES
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.2mA
@ 250VAC 50Hz: 0.4mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
D
V
E
MINIMUM INSERTION LOSS IN dB
CURRENT FREQUENCY-MHz
RATING .15 .50 1.0 5.0 10 30
1A 28 35 38 38 40 40
3A 20 25 30 38 40 40
6A 12 18 24 35 40 40
6A (G3Q) 15 20 24 35 40 55
10A 4 10 13 28 35 40
10A (G3C) 10 15 15 25 30 35
10A (G3Q) 10 12 15 30 32 45
15A 4 10 13 28 35 40
20A 8 10 15 25 30 35
COMMON MODE (L-G) IN 50 OHM SYSTEM
20 dB
0 dB
10K
60 dB
80 dB
40 dB
100K
1M
10M
INSERTION LOSS (TYPICAL)
03GENG3E
06GENG3E
COMMON MODE
COMMON MODE
DIFF. MODE
DIFF. MODE
20GENG3E
DIFF.MODE
100K
40 dB
20 dB
0 dB
10K
80 dB
60 dB
1M
10M
COMMON MODE
ELECTRICAL SCHEMATIC
G
N
L
E
L
N
I
R
Cx
Cy
Cy
G'
D
L
O
A
N'
L'
R: 1M /-R ONLY
1. Snap-in mounting type to reduce labor cost.
Compact and reliable at low cost.
2. Bleeder resistor can be added with suffix "-R"
on part numbers,except G3H,G3V,W3V,G3J,W3J,types.
3. Optional side snap-in mounting clip type with suffix (H) on part
numbers.
4
5. With optional Y-Cap from 100pF to 3300pF.
6. Safety under apply for 03/06/10GENG3U(H) series.
. All part numbers are UL recongnized, CSA certified and VDE
approved.
INTRODUCTIONS
COMPONENTSCOMPONENTS
UL, CSA approved to 4A 115/250V
UL, CSA approved to 8A 115/250V
UL, CSA approved to 13A 115/250V
VDE approved to 16A/250V
***
VDE approved to 8A/250V
VDE approved to 10A/250V
**
*
**
01GENG3E/W3E/-R 6.5
03GENG3E/W3E/G3U(H)/-R 2.5
03GENW3ES/-R 2.5
03GENG3Q/W3Q/-R 4
06GENG3E/W3E/G3U(H)/-R 0.8
06GENG3Q/W3Q/-R 1.5
0.1 2200 1M
06GENW3ES/-R 0.8
10GENG3E/W3E/G3U(H)/-R 0.2
10GENG3C/W3C/-R 0.4
10GENG3Q/W3Q/-R 0.3
10GENW3ES/-R 0.2
15GENG3E/W3E/-R 0.2
20GENG3E/W3E/-R 0.3
PART NO. Cx (uF) L (mH) Cy (pF) R ( )
*
**
** *
**
**
IEC INLET FILTERS