IMG 1004 - Software Installation and Setup
127
Starting GateControl EMS
Topic Location:
IMG 1010-Installation and Setup Guide > IMG 1010-Software Installation and Setup
-or-
IMG 1004-Installation and Setup Guide > IMG 1004-Software Installation and Setup
Overview:
The procedure below will explain how to start the GCEMS application. At this point, the files
IMG_10.5.x.xxx.bin and IMGUserInterface_10.5.x.xxx.bin files have been transferred to the
GCEMS server and have been installed. There are two ways to start the GCEMS and ClientView
processes on the GCEMS server. The first way is by using the icons on the desktop if access to
the Linux server is allowed through VNC or some other remote desktop application. The
second method is used if remote access to the desktop is not allowed and access to the server
is accomplished through something like an SSH telnet session.
Related Topics
GCEMS Installation Script
Using ICONS on Desktop.
1. Login to the GCEMS server as user excelsw.
username: excelsw
password: excelsw
Once logged into the server, doubleclick on the StartGCEMS icon on the desktop. A
screen like below will appear and all the processes will start automatically. To configure
the IMG open ClientView and start a new configuration by either using the Configuration
Wizard or load an existing .csa file and allow ClientView to configure the IMG. See
Starting ClientView