Printed in China
9NK5010061000
07P03-CH-NM
INSTALLATION MANUAL
CAUTION:
•Potential hazard of glass particles if lamp ruptures. Please have an EIKI Authorized Dealer or Service Center
replace lamp if rupture occurs.
• Do not remove the lamp unit directly after operation of the projector. The lamp may be extremely hot. Wait at
least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool before
removing the lamp unit.
■
It is recommended that the lamp be replaced when the remaining lamp life becomes 5% or less, or when you notice a signifi-
cant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display.
Removing and Installing the
Lamp Unit
Info
• Make sure that you remove the lamp unit by the
handle. Do not touch the glass surface of the lamp
unit or the inside of the projector.
• To avoid injury to yourself and damage to the lamp,
be sure to carefully follow the steps below.
• Do not loosen other screws except for the lamp unit
cover and lamp unit.
(Only the silver screws are loosened.)
1 Press on the projector or on
the remote control to put the projec-
tor into standby mode.
• Wait until the cooling fan stops.
Warning!
• Do not remove the lamp unit from the projector
right after use. The lamp and parts around the
lamp will be very hot and may cause burn or
injury.
2 Disconnect the power cord.
• Unplug the power cord from the AC socket.
• Leave the lamp until it has fully cooled down
(about 1 hour).
3 Remove the lamp unit cover.
• Loosen the user service screw (1) that se-
cures the lamp unit cover. Remove the lamp
unit cover (2).
4 Remove the lamp unit.
• Loosen the securing screws (two for each lamp)
from the lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the arrow.
At this time, keep the lamp unit horizontal and
do not tilt it.
LAMP UNIT (LAMP/CAGE MODULE) FOR PROJECTOR
Model AH-50001/AH-50002
5 Insert the new lamp unit.
• Press the lamp unit firmly into the lamp unit
compartment. Fasten the securing screws.
• Be sure that AH-50001 and AH-50002 are re-
spective type.
6 Replace the lamp unit cover.
• Align the lamp unit cover and slide it to close.
Then tighten the user service screw to secure
the lamp unit cover.
Info
• If the lamp unit and lamp unit cover are not cor-
rectly installed, the power will not turn on, even if
the power cord is connected to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
• Make sure to reset the lamp timer only when re-
placing the lamp. If you reset the lamp timer and
continue to use the same lamp, this may cause the
lamp to become damaged or explode.
1 Connect the power cord.
•
Plug the power cord into the AC socket of the projector.
2 Reset the lamp timer.
For Lamp 1
• When you reset the timer for AH-50001, while
simultaneously holding down and ,
press
on the projector.
• “LAMP 1 100%” is displayed, indicating that the
lamp timer is reset.
For Lamp 2
• When you reset the timer for AH-50002, while
simultaneously holding down and ,
press on the projector.
• “LAMP 2 100%” is displayed, indicating that the
lamp timer is reset.
STANDBY-ON button
Power cord
1
2
User service screw
Securing screws
Handle
Compartment for
AH-50001
Compartment for
AH-50002
AH-50002
AH-50001
For Lamp 1
For Lamp 2
User service
screw
To AC socket
Power cord
ENTER button
MENU button
H&V LENS
SHIFT
button
STANDBY-ON button
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-242-3454
U.S.A. ONLY
AH50001_2_OptionLamp.p65 06.12.20, 9:36 AM1