Emulex NP02 Printer User Manual


 
UNIX TCP/IP 4-23
Local Login
1) Connect an ANSII compatible terminal or a PC running an ANSII
terminal emulation program to the printer server serial or console port.
Emulex default port configuration is set for 9600 bps, 8 data bits, no
parity, 1 stop bit, DTE type, with softcopy emulation.
2) Press
ESC twice.
This initiates communication between the console terminal and the
printer server serial port.
3) Verify banner.
When the connection is made, the printer server login banner is
displayed.
4) At Enter Username or Help>, enter any two characters.
5) At Server>, enter su:
>
Server> su
This gives you supervisor status.
6) At Password>, enter system:
>
Password> system
where system is the default privileged password which does not echo
back.
7) Change terminal emulation mode to ANSI.
>
Server>> change port type ANSI
8) At the Server>> prompt, view or change current parameters.
Refer to the list of commands in the
Command Reference Guide.
9) Logout of the printer server:
>
Server>> logout