Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
3-150
It is recommended that a conventional channel LID stored in the
CEC/IMC Manager be given the same alias as the corresponding
conventional channel LID at the System Manager, i.e. if a System
Manager exists, changing a conventional channel alias at the
CEC/IMC Manager is possible but not recommended. This will
ease conventional channel identification during patch operations since a
console communicates with a conventional channel by its channel
number, not its LID number.
A console never uses a conventional channel LID. The
conventional channel LID is only sent to trunked sites during a
conventional channel-to-trunked group patch.
Table 7 Conventional Channel Locations (Example with Max.
Conv. Channels per CEC/IMC = 64) (Non-Inclusive Listing)
CEC/IMC
SWITCH
ASSIGNMENT
NUMBER
CIA RACK
NUMBER
CIA RACK
CHANNEL
NUMBER
NETWORK
CONV.
CHANNEL
NUMBER
33111
33 1 32 32
33 2 1 33
33 2 32 64
34 1 1 65
34 1 32 96
34 2 1 97
34 2 32 128
35 1 1 129
35 1 32 160
35 2 1 161
35 2 32 192
36 1 1 193
36 1 32 224
NOTE