LBI-39224
3-187
data is not successfully broadcast to all required devices a "MOM
Communication Error" or "Device not active" notify box will be
displayed. The assigned Controller Board (device type and assignment
in the I/O definition) must be installed and active for the event
definition to operate. Normally, only modified event definitions are
sent to the MOM.
Send
Choose the
Send
button to send the currently selected I/O event data to
the MOM Controller Board. The key and message event information
will be sent to but not stored in MOM Controller NOVRAM.
Send All
Choose the
Send All
button to send/resend all I/O event
configurations. This is useful to refresh all I/O configurations if a
Controller Board or console has been replaced or upgraded and has lost
its I/O event data.
Save All
Choose the
Save All
button to save all I/O event configurations to the
CEC/IMC Manager hard disk.
Close
Choose the
Close
button to exit the
Auxiliary I/O Event Configuration dialog box and return to the
CEC/IMC Manager main window. If any changes have been made and
not saved, you will be prompted (Write Changes to Disk?) to save
and exit (
Yes
), exit without saving (
No
), or cancel the
Close
command and remain in the dialog box (
Cancel
).
3.19 ACTIVATE TDM BUS SLOTS
No interface modules will receive the new bus and slot settings stored
in the MOM until each one is reset. These are the settings from the
various interface module configurations performed earlier in the setup
procedure which were sent to the MOM when
Send
was performed
from those dialog boxes. This can be done by cycling power or by
individually resetting each interface module's Controller Board. This
should be done after both the bus and slot configurations have been
sent to the MOM.
If the CEC/IMC is equipped with firmware V4.03 or later, this can be
done automatically from the CEC/IMC Manager by selecting the