LBI-39224
A-4
LOGGED
ERROR
MESSAGE
LOGGED
ERROR
DATA
CAUSE/
CORRECTIVE
ACTION
E03-028:
LINK FAIL -
CONSOLE
0000h = CIM control
data link failure.
0001h = Attached
console is "Logged
Out" or "Disabled."
For a C3 Desktop/
Modular console,
0001h indicates the
Translator-to-console
control data link has
failed.
Control data link failure between
CIM and console.
E03-029:
LINK FAIL -
RECORDER (Reserved
for future use.)
Control data link failure between
LRIM and logging recorder.
E03-030:
LINK FAIL - RSM
MONITOR
Control data link failure between
RIM and RSM equipment.
E03-031:
LINK FAIL - CTIS
Control data link failure between
PIM/CTIM and Jessica/CTIS
equipment.
E03-035:
LINK FAIL - HDLC
CHANNEL A
No information is
contained in the data
word.
The idle flag sequence cannot be
detected on HDLC channel A.
Corrective Action:
To clear the
error, proper connection to HDLC
channel A, via the backplane
connector, must be made to a
remote station that continuously
transmits idle flag sequences at the
correct bit rate.
E03-036:
LINK FAIL - HDLC
CHANNEL B
Lower byte of the
data word contains
01h, indicating
channel B. The upper
byte of the data word
contains the number
of the Audio Board
that stopped
responding.
An Audio Board at a secondary
address on HDLC channel B that
was previously responding to polls
has stopped responding.
Corrective Action:
To clear the
error, an Audio Board set to the
same number that caused the error
must be placed in the system, or
the Controller Board that
originated the error must be reset.