LBI-39224
A-6
LOGGED
ERROR
MESSAGE
LOGGED
ERROR
DATA
CAUSE/
CORRECTIVE
ACTION
E08-18:
DEVICE CONFLICT -
CONTROL BOARD
No information in the
data word.
A Controller Board device
type/assignment setting is
conflicting with another board's
setting. For example a VMIM 5
and a MIM 5 will conflict with
each other. The main information
is the device type/assignment in the
error heading. With the correct
hardware revision, the ID LED will
also be flashing on the offending
board. Also, sometimes this error
only applies to one board.
(Example CCI, or second MOM
mistakenly installed in main
CEC/IMC rack).
Corrective
Action:
The offending board must
be removed and its type/assignment
setting must be changed to not
conflict with another device. The
other device should also be
displaying this error and it should
also be reset.
E09-139:
T1/E1 INTERFACE -
LOSS OF SIGNAL
Data field is the
T1/E1 Interface Card
affected (1-8).
The T1/E1 Interface Card has lost
its T1/E1 signal.
E09-140:
T1/E1 INTERFACE -
LOSS OF FRAME
SYNC
Data field is the
T1/E1 Interface Card
affected (1-8).
A valid T1/E1 receive framing
sequence no longer exists at the
T1/E1 Interface Card. Two
possible causes would be that the
frame format changed at one end of
the T1/E1 link or loss of the T1/E1
signal.
E09-141:
T1/E1 INTERFACE -
EXCESSIVE FRAME
SLIPS
Data field is the
T1/E1 Interface Card
affected (1-8).
A Frame Slip occurs when a
clocking frequency mismatch (at
the card level) causes received
frames to be repeated or discarded.
Excessive frame slips indicate a
clock failure on the T1/E1 Interface
Card.