LBI-39224
B-1
7.2 APPENDIX B - LOGGED WARNING
DEFINITIONS
LOGGED
WARNING
MESSAGE
LOGGED
WARNING
DATA
CAUSE/
CORRECTIVE
ACTION
W00-xxx:
UNKNOWN
WARNING
(none) A warning has been generated
within the CEC/IMC, but the
CEC/IMC Manager cannot
determine what it is. This is
usually a result of a Controller
Board residing in the system with
firmware prior to version 2.00 or
with a firmware version more
recent than the CEC/IMC
Manager's software version.
Corrective Action:
Ensure all
Controller Boards in system are
equipped with firmware version
2.00 or greater and the CEC/IMC
Manager contains a software
version greater than or equal to the
most recent Controller Board
firmware being used.
W01-048:
UNDEFINED -
CALLEE TYPE
The callee type value
that generated the
warning.
Unknown callee type was found.
W01-049:
UNDEFINED -
CALLER TYPE
The caller type value
that generated the
warning.
Unknown caller type was found.
W02-028:
OUT OF RANGE -
CONSOLE NUMBER
Console number that
generated the
warning.
Console number found that was not
in the allowed range of 1 – 32.
W02-032:
OUT OF RANGE -
BUS_SLOT
Low byte contains
bus number. High
byte contains slot
number.
Bus or slot number found that was
greater than the maximum number
allowed.
W02-033:
OUT OF RANGE -
AUDIO CHANNEL
Audio channel
number that generated
the warning.
Audio channel number found that
was not in the allowed range.