LBI-39224
B-8
LOGGED
WARNING
MESSAGE
LOGGED
WARNING
DATA
CAUSE/
CORRECTIVE
ACTION
W10-114:
TIMEOUT - SAFETY
TIMER
Channel number that
was cleared.
The NIM (StarGate systems) has
received no activity on an active
channel for approximately ten (10)
minutes. The NIM will clear the
channel at this point and issue this
warning.
W11-118:
REDUNDANT -
PRIMARY/
SECONDARY
SWITCH
The GSC address of
the secondary node
that switched.
Secondary MIM Controller Board
has switched to become a primary
MIM Controller Board.
W12-036:
LINK FAIL - HDLC
CHANNEL B
The Audio Board
number that failed to
respond.
An Audio Board with slots
allocated to it has failed to respond
to S-Frame polls from the
Controller Board. This warning
could indicate the high speed serial
link (HDLC Protocol) between the
Controller Board and one of its
Audio Boards is not functioning.
This warning will also be generated
if slots are allocated but the board
is not installed in the switch.
W13-099:
CALLEE NOT FOUND
- CIM MODULE
TABLE
Callee ID that could
not be found.
The given callee ID could not be
found in the CIM Module Table.
W13-100:
CALLEE NOT FOUND
- CIM CHANNEL
DATABASE
Callee ID that could
not be found.
The given callee ID could not be
found in the CIM Channel
Database.
W14-101:
NDC DATA - SUM
DATA
Channel number. An attempt was made to sum data
on the same audio channel.
W15-129:
UNAVAILABLE -
SAID VALUE
Number of SAIDs
allocated to this
switch.
All SAIDs (System Assigned
Group IDs) allocated to this switch
are currently in use by other
patches/simulselects.