LOGGED
WARNING
MESSAGE
LOGGED
WARNING
DATA
CAUSE/
CORRECTIVE
ACTION
W15-144:
UNAVAILABLE -
FAILSOFT PATCH
Data field contains
Logical ID (in hex) of
the console that
attempted to perform
a patch.
The attempted action was denied
because the system was in Failsoft
operation and the Failsoft Patch
feature was not enabled. The
system must be returned to trunked
operation or the Failsoft Patch
feature license must be installed for
the patch to succeed.
W16-017:
VALUE IN USE -
MULTINODE
Switch ID that is
duplicated.
A NIM received a call from another
CEC/IMC with the same switch ID
as this CEC/IMC. (Set by the
MOM Controller Board assignment
DIP switch). For proper call
arbitration on a StarGate network,
each CEC/IMC must have a unique
switch ID.
W16-129:
VALUE IN USE - SAID
VALUE
The SAID value. An attempt was made to create a
patch/simulselect with a SAID
(System Assigned Group ID) that
was already being used by another
patch/simulselect.
W17-120:
AUXILIARY I/O -
MOM ERROR ARRAY
(none) The MOM auxiliary I/O
error/warning alarm list is full.
This should not normally occur.
The list has an entry for each
possible event.
Corrective
Action:
Reset the MOM and
resend the auxiliary I/O definitions
from the CEC/IMC Manager.
W17-130:
AUXILIARY I/O-
STATE CHANGE
This warning uses
specially formatted
data to identify the
event and the current
state.
A defined auxiliary I/O event has
changed states – active to inactive
or inactive to active. This warning
provides a record of Aux. I/O
activity and, at the CEC/IMC
Manager, it may be suppressed for
any Aux. I/O event.