LBI-39224
B-10
LOGGED
WARNING
MESSAGE
LOGGED
WARNING
DATA
CAUSE/
CORRECTIVE
ACTION
Notes for W18-xxx warnings: Controller Boards with firmware versions prior to 2.12
do not log these warnings. For Controller Boards with firmware versions 2.12 or
greater but less than 3.00, W18-132 will be logged for changes in device type, version
number, and date/time stamp. For these versions also note the following: 1) the node
ID of the source node will always be FFh, 2) the upper byte of the data word will
contain the new device type value and the lower byte will be either the previous device
type value, if the device type has changed, or the value FFh. For CCI Controller Board
version 2.12 and greater, the source node ID will always be FFh.
W18-131:
NOVRAM CLEAR -
NEW DEVICE
ASSIGNMENT
Previous assignment
value in upper byte,
current assignment
value in lower byte.
Non-volatile RAM (NOVRAM)
cleared on Controller Board due to
a change in device assignment DIP
switches. This only occurs on
certain device personalities.
W18-132:
NOVRAM CLEAR -
NEW DEVICE TYPE
Previous type value in
upper byte, current
type value in lower
byte.
Non-volatile RAM (NOVRAM)
cleared on Controller Board due to
a change in device type DIP
switches.
W18-133:
NOVRAM CLEAR -
INVALID CHECKSUM
Either the computed
checksum, or the
value 0055h
Non-volatile RAM (NOVRAM)
cleared on Controller Board due to
one of the following: 1) computed
checksum did not match the stored
checksum, 2) a key value stored in
NOVRAM did not match the value
in the 80C186 ROMs (e.g. version
number, date/time stamp, etc.).
W19-115:
DENIED - PATCH/
SIMULSELECT
The SAID value
assigned to the
patch/simulselect.
A site has denied the activation of
a patch or simulselect. If multiple
sites deny it, only the first denial
received is logged.
Note for W20-xxx warnings: These warnings are applicable only for StarGate systems
that have conventional channels installed on more than one CEC/IMC in the StarGate
network.