LBI-39224
3-30
by comparing the CEC/IMC Manager and CEC/IMC list boxes in the
Site Channel Configuration dialog box. Ensure that the CEC/IMC
configuration is correct, then choose the CEC/IMC to Disk button to
restore the CEC/IMC Manager configuration database (for the selected
interface module).
Channel Selection
Select a channel (1 thru 32) for configuration from the CEC/IMC
Manager list box, only one channel may be selected at a time. The
selected channel and its configuration data will be displayed in the edit
fields above the CEC/IMC Manager list box.
Input Signal Level (dBm)
This setting establishes the signal level in dBm (600-ohm impedance;
0 dBm = 1 milliwatt) applied to the selected channel's line input. Enter
(type) the required value in the text box. The setting should be equal to
the voice peak (test tone) level applied to the channel's line input.
Voice peak levels are +10 dBm greater than average voice levels.
Valid range is -25.0 dBm to 12.0 dBm, adjustable in 0.5 dBm
increments. The program automatically rounds-off non-0.5 dBm
fractional entries to the nearest 0.5 dBm point. Input Signal Level
default = 0 dBm.
If Automatic Level Control (ALC) is disabled for the selected
channel, subtract 1.5 dBm from the required Input Signal
Level setting. For example, if the required input signal level is
-10 dBm, enter -11.5 dBm. ALC is disabled by setting the
ALC text box to "NO."
LBI-38938 contains a line level adjustment overview section which
contains general information and general recommendations for both
input and output level settings.
Output Signal Level (dBm)
This setting establishes the signal level in dBm (600-ohm impedance;
0 dBm = 1 milliwatt) sent out by the selected channel's line output. The
setting specifies the voice peak (test tone) level sent out by the channel.
The valid range is -25.0 dBm to 13.0 dBm, generally in 0.5 dBm
increments, select the required value from the drop-down list box.
Output Signal Level default = 0 dBm.
NOTE