Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
3-32
For example, if the currently selected site-type interface module is a
20-channel MIM with five (5) Audio Boards addressed 1 thru 5,
Bus/Slots Equipped for channels 1 thru 20 must be "YES."
In earlier CEC/IMC firmware/software releases, slot
allocations could only be made contiguously starting with
channel one (1). In some systems this produced slot allocation
inefficiencies, i.e., some slots had to be allocated but were
never used. CEC/IMC software/firmware release 5.0 (and
later) provides non-contiguous slot allocations. In this release,
only those slots actually required need be allocated. For
example, channels 1 and 4 can be allocated slots without
allocating slots to channels 2 and 3.
Notch Filter
DO NOT enable the 2175 Hz Notch Filter for any channel if
the respective Audio Board part number is 19D903302P1 (any
revision).
Each Audio Board channel is equipped with a 2175 Hz notch filter
circuit which when enabled eliminates destructive interference of the
channel's 2175 Hz transmit keying tone. In some cases, this destructive
interference or "talk down" can cause incorrect (early) trunked site
channel drops. To enable the selected channel's notch filter, enter
"YES" in the Notch Filter text box. Notch Filter default = "NO"
(disabled).
ALC
DO NOT enable ALC for any channel if the respective Audio
Board part number is 19D903302P1 (any revision).
Automatic Level Control (ALC) provides compensation for signal level
variances in a channel line input signal. As required, enable ALC for
NOTE
CAUTION
CAUTION