Extech Instruments 42515 Clock User Manual


 
42515-EU V4.1 2/09
9
Specifications
Infrared Thermometer (Non-contact) Specifications
Range / Resolution -50.0 to 800.0
o
C (-58.0 to 1472.0
o
F) Resolution: 0.1
o
Accuracy -50 to -1°C (-58 to 30°F) ± 2.0%rdg or ±3°C/6°F
whichever is greater
-0.5 to 65°C (31°F to 150°F ) ± 2.0%rdg or ±2.5°C/4.5°F
whichever is greater
66 to 315°C (151°F to 600°F) ± 2.0%rdg or ±2°C/4°F
whichever is greater
316 to 800°C (600F to 1472°F) ± (2.5%rdg + 2.5°C/5°F)
Note: Accuracy is specified for the following ambient temperature
range: 23 to 25°C (73 to77°F)
Emissivity 0.10 to 1.00 adjustable (Automatic adjust above 212
o
F or 100
o
C)
Field of View D/S = Approx. 13:1 ratio (D = distance; S = spot or target)
Laser pointer Class 2 laser < 1mW power; Wavelength is 630 to 670nm
IR Spectral response
8 to 14 μm (wavelength)
Type K Thermocouple (Contact) Specifications
Range / Resolution -50.0 to 1370.0
o
C (-58.0 to 1999.9
o
F)
2000°F to 2498°F*
0.1
o
Accuracy ± (1.5% of rdg + 1ºC/2ºF
Note: Accuracy is specified for the following ambient temperature
range: 18 to 28ºC (64 to 82ºF)
* The supplied thermocouple is rated for 250
o
C (482
o
F).
General Specifications
Display Backlit LCD display with function indicators
Display update rate 1 second approx.
Operating Temperature 0
o
C to 50
o
C (32
o
F to 122
o
F)
Operating Humidity 80% Relative Humidity max.
Power Supply 9V battery
Automatic Power Off Meter shuts off automatically after 7 seconds
Weight 180g /6.4 oz.
Dimensions 82 x 42 x 160mm (3.2 x 1.6 x 6.3”)
Copyright © 2009 Extech Instruments Corporation
All rights reserved including the right of reproduction in whole or in part in any form.