FARGO electronic DTC500 Series Printer User Manual


 
RESTRICTED USE ONLY Fargo Electronics, Inc.
DTC500 Series Card Printer/Encoders User Guide (Rev. 6.0)
250
Adjusting the Magnetic TOF
Use this setting to position the magnetic data at the correct distance from the leading edge of
the card.
The Magnetic TOF is the distance from the edge of the card to the Start Sentinel (SS).
The Start Sentinel marks the beginning of the encoded data. (Note: According to the
magnetic recording standard (ISO 7811), the correct Start Sentinel distance is 0.293
inches ± 0.020 inches (7.44 mm ± 0.51 mm) from the leading edge of the card.)
Step Procedure
1 a. From the application program, print and encode a test card.
b. Measure this distance by making the data visible using a magnetic viewer or
developer solution.
c. Alternatively, use a Magnetic Card Analyzer to measure the Start Sentinel
distance.
2 a. Use a magnetic viewer or developer solution or spray to make the magnetic
data visible (in order to identify the Start Sentinel as the first set of magnetic
lines or first one-bit, which are visibly closer together than the large number
of evenly spaced lines or leading zero-bits that fill the space to the edge of
the card, as shown on the next page).
b. Use a magnifying device with a built-in measuring scale to measure the
distance from the edge of the card to the Start Sentinel in the data, as shown
on the next page.
3 If the Start Sentinel is too far from the leading edge of the card, reduce (or make
negative) the Magnetic TOF setting needs.
OR
If the Start Sentinel is too close to the leading edge of the card, increase (or
make positive) the Magnetic TOF setting needs.
4
Select MENU, Setup Printer and Magnetic TOF.
5 Record the Magnetic TOF value on the test card last printed.
Continued on the next page