Fortinet 5003 Switch User Manual


 
FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
96 01-30000-85717-20081205
config FortiSwitch-5003A CLI reference
switch fabric-channel physical-port
Use this command to change the administrative status of FortiSwitch-5003A fabric channel interfaces
(bring each interface up or down) and configure each fabric channel interface to receive heartbeat
packets from FortiGate-5001A or 5005FA2 fabric channel interfaces.
Syntax
config switch fabric-channel physical-port
edit <interface_name>
set native-vlan <id_number>
set allowed-vlans <id_numbers>
set stp-state {disable | enable}
end
Variables Description Default
edit <interface_name> Enter the name of the FortiSwitch-5003A fabric channel
interface to configure. You cannot configure physical port
settings for a trunk. You can configure physical port settings for
interfaces that have been added to a trunk.
For the fabric channel <interface_name> can be:
slot-2/1 used to connect the fabric channels of two
FortiSwitch-5003A boards installed in the same chassis.
slot-3 FortiGate chassis slot 3.
slot-4 FortiGate chassis slot 4.
slot-5 FortiGate chassis slot 5.
slot-6 FortiGate-5140 chassis slot 6.
slot-7 FortiGate-5140 chassis slot 7.
slot-8 FortiGate-5140 chassis slot 8.
slot-9 FortiGate-5140 chassis slot 9.
slot-10 FortiGate-5140 chassis slot 10.
slot-11 FortiGate-5140 chassis slot 11.
slot-12 FortiGate-5140 chassis slot 12.
slot-13 FortiGate-5140 chassis slot 13.
slot-14/f8 FortiGate-5140 chassis slot 14 or
FortiSwitch-5003A front panel slot 14/F8.
f7 FortiSwitch-5003A front panel slot F7.
f6 FortiSwitch-5003A front panel slot F6.
f5 FortiSwitch-5003A front panel slot F5.
f4 FortiSwitch-5003A front panel slot F4.
f3 FortiSwitch-5003A front panel slot F3.
f2 FortiSwitch-5003A front panel slot F2.
f1 FortiSwitch-5003A front panel slot F1.
heartbeat {disable |
enable}
Enable or disable listening for heartbeat packets from
FortiGate-5001A or 5005FA2 fabric interfaces.
If you enable listening for heartbeat packets on interfaces
added to link aggregation trunks the FortiSwitch-5003A board
can detect if a FortiGate-5001A or 5005FA2 board is no longer
available. You must configure the FortiGate-5001A or 5005FA2
board to send heartbeat packets using the following
FortiGate-5001A or 5005FA2 CLI command:
config system global
set fortiswitch-heartbeat enable
end
disable
status {down | up} Bring the interface up or down. up