28 Fortinet Inc.
Front panel features Getting started
Front panel features
Figure 3 shows the location of the FortiGate-4000 chassis front panel components.
The front panel contains and provides access to up to 10 FortiBlade-4010 modules
and the KVM switch module.
Figure 3: FortiGate-4000 chassis front panel
Table 1: FortiGate-4000 chassis
physical description
Dimensions 42.6 x 17.7 x 67.0 cm 16.78 x 6.97 x 26.40 in.
(W x H x D)
Weight Minimum: 28 kg (61 lb) (no FortiBlade-4010 modules installed)
Maximum: 50 kg (110 lb) when full configured.
FortiBlade-4010: 2 kg
Operating Environment Temperature: 0 to 35°C
Relative humidity: 10% to 90% (Non-condensing)
Storage Environment Temperature: -20 to 80°C
Relative humidity: 10% to 90% (Non-condensing)
Power dissipation Minimum: 1050 watts
Maximum: 2100 watts
Power Requirements 100 ~ 230 VAC input
AC inlet x 3
Power Consumption Minimum: 1.3 KVA (3+1 redundancy)
Maximum: 2.6 KVA (6+1 redundancy)
Note: Do not operate the FortiGate-4000 chassis with open slots on the front panel. For
optimum cooling performance, all front panel slots must either contain a FortiBlade-4010
module or be covered by an empty slot cover.
POWER ON/OFF
LAN 1LAN 2
PWR/KVMSTATUS
KVM/ACCESS