Fujitsu DX440 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
886
Operated Volume
Select whether to notify when the volume has been created or deleted. When notifying, select the
notification method.
Power off/on Apply Firmware
Select whether to notify when the ETERNUS DX Disk storage system is turned off/on or when the
controller firmware is changed in hot mode. When notifying, select the notification method.
SDP Usage Rate Over Lv1
Select whether to notify when an SDP Policy Level 1 (Informational) event occurs. When notifying,
select the notification method.
SDP Usage Rate Over Lv2
Select whether to notify when an SDP Policy Level 2 (Warning) event occurs. When notifying, select
the notification method.
SDP Usage Rate Over Lv3
Select whether to notify when an SDP Policy Level 3 (Error) event occurs. When notifying, select the
notification method.
Copy Table Size Usage Rate Over
Select whether to notify when the copy table usage exceeds the threshold. When notifying, select
the notification method.
Trial copy license expired
Select whether to notify when a copy trial license expiration event occurs. When notifying, select the
notification method.
No Free Space on ODX Buffer Volume
Select whether to notify when an insufficient free space event for an ODX Buffer volume occurs.
When notifying, select the notification method.
SED Network Error Recovered
Select whether to notify when the communication between the ETERNUS DX Disk storage system
and the key server is recovered. When notifying, select the notification method.
FC CA Port Link Status Changed
Select whether to notify when a link down occurs after an FC link is established and the link status is
changed. When notifying, select the notification method. Note that a change in the link status due
to user operation is not notified.
A change in the link status for all the FCs is notified. The notification is reported regardless of the
type (8G FC or 16G FC), the port mode (CA, RA, CA/RA, Initiator), and the transfer rate. The following
FC link status types can be detected and notified:
- The link status between the ETERNUS DX Disk storage system and a directly connected server
- The link status between the ETERNUS DX Disk storage system and switches
The FC link status can be checked in the [Port Detail] screen. Refer to "10.1.2.3 All Channel
Adapters" (page 636) for details.