Fujitsu DX440 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
907
A storage system or volume cannot be specified as the destination in the following cases:
- Concurrent upgrade of firmware is in progress at the destination storage system
- The RAID group to which the destination volume belongs to has an ECO mode schedule configured
- The Thin Provisioning Pool (TPP) to which the destination volume belongs has an ECO mode schedule
configured
- The destination volume is specified as a RAID migration source or destination
- The capacity of the RAID group to which the destination volume belongs is being expanded
- Encryption is in progress for the destination volume
- The capacity of the destination volume is being expanded
- The destination volume is specified as the destination for another Storage Migration operation
- An ODX Buffer volume is selected as a migration destination volume
Stop access from the host to both the source LUN and destination volume.
When "Migration + Full Compare" or "Full Compare" is specified for the operation mode, stop the host
access to all of the volumes in the migration destination storage system.
Do not specify a volume that has copy sessions as a source or destination.
Do not specify a volume as the source when formatting is in progress.
Do not execute the [Start RAID Group Diagnosis] function or the [Start Disk Diagnosis] function on the
destination storage system.
When "Migration + Full Compare" or "Full Compare" is specified for the operation mode, the time to com-
plete the operation after data migration is increased significantly.
Download a template to create a Storage Migration setting file. Refer to "11.2.11.2 Download Template
File for Storage Migration Settings" (page 912) for details.
Change the mode of the FC port that is used on the destination storage system to "Initiator". Refer to
"9.2.3.11 Modify Port Mode" (page 571)
for details.
Specify detailed parameters for the FC-Initiator port that is used on the destination storage system. Refer
to "9.2.3.7 Modify FC Port Parameters" (page 531)
for details.
A started Storage Migration can be suspended, restarted, and stopped in volume units. Refer to
"11.2.11.6 Suspend Storage Migration" (page 917)
, "11.2.11.5 Restart Storage Migration" (page 916), or
"11.2.11.7 Stop Storage Migration" (page 918)
for details.