Fujitsu M10-4S Server User Manual


 
Note -
Reinstall the crossbar cables (optical) in their original positions by referring to the
notes that you made prior to the start of maintenance.
Note -
In the case of a dual power feed, connect the power cords in their original positions by
referring to the record that you made before the start of maintenance.
XSCF>
diagxbu -y -b 00 -p 02
3.
Connect all c rossb ar cables (optical) to the crossbar un it.
For details, see "25.5 Installing a Crossbar Cable (Optical)."
16.6 Restoring the System
This section describes the procedure for restoring the system after installing the
crossbar units. The restoration procedure differs depending on the maintenance type
as follows:
Active/Cold maintenance
Inactive/Cold maintenance
System-stopped maintenance
16.6.1 Active/Cold maintenance
1.
Connect all the po wer c ords to the po wer s upply unit of the crossbar box
requiring mai nten ance.
For details, see "6.5.1 Installing the power cord."
2.
Execute the diagxbu command to diagno se the cro ssbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is incorporated into the physical partition, and the physical
partition is powered on.
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
02: PPAR-ID of the destination where the chassis to start the diagnosis is
connected (You can specify only one of these.)
3.
Pow er on the physical p artition requiring main t enan ce.
For details, see "6.3 Powering On the Physical Partition Requiring Maintenance."
4.
Close t he rack d oor.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
December 2013304