Fujitsu M8000/M9000 Server User Manual


 
24 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1060 November 2007
6589546 prtdiag(8) command does not show all I/O
devices of the following cards:
SG-XPCIE2FC-EM4 Sun StorageTek
Enterprise Class 4Gb Dual-Port Fibre
Channel PCI-E HBA
SG-XPCIE1FC-EM4 Sun StorageTek
Enterprise Class 4Gb Single-Port Fibre
Channel PCI-E HBA
Use prtdiag -v for full output.
6589644 After added the system board by DR, when the
switching occurred on the redundant XSCF
Units, the domain console may hang up.
The console can be recovered by pressing
Ctrl-q (the "Ctrl" key and the "q" key).
6589833 The DR addboard(8) command might cause a
system hang if you are adding a Sun
StorageTek Enterprise Class 4Gb Dual-Port
Fibre Channel PCI-E HBA card (SGXPCIE2FC-
QF4) at the same time that an SAP process is
attempting to access storage devices attached
to this card. The chance of a system hang is
increased if the following cards are used for
heavy network traffic:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
There is no workaround. Check for the
availability of a patch for this defect.
6592302 Unsuccessful DR operation leaves memory
partially configured.
Try deleteboard(8) again.
6600730 Extra characters appear in a boot message
string.
The extraneous characters can be safely
ignored.
TABLE 4 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround