U41243-J-Z156-1-76 9
Introduction Technical data
1.6 Technical data
Electrical data
Rated voltage range 100 V - 120 V
200 V - 240 V (auto sense)
Rated voltage tolerance +6 % / -10 %
Frequency 50 Hz / 60 Hz
Rated current at 100V - 120 V 12 A
Rated current at 200V - 240 V 7 A
Effective power 1247 W
Apparent power 1271 VA
Heat emission 4014 kJh
Building fuse 16 A
Protection class I
Dimensions and weight
Height (mm) 312 (seven height units)
Width (mm) 445
Depth (mm) 712
Weight (kg) max. 60 (maximum configuration)
Environmental conditions (according to DIN EN 60721-3-x)
Operating climate (Class 3K2):
Temperature (°C) 10 to 35
Relative humidity(%) 5 to 85
Environmental conditions/transport (Class 2K2):
Temperature (°C) -25 to 60
Relative humidity (%) 15 to 98
Mechanical environmental conditions
Operation Class 3M2
Transport Class 2M2