GE 82-POE Switch User Manual


 
Chapter 4: Web-Based Management
GE-DS-82 and 82-PoE Ethernet Managed Switch User Manual 133
This page includes the following fields:
OBJECT DESCRIPTION
PoE PSU Status PoE PSU Status shows status of power supply for PoE output.
PoE Temperature Unit 1 Display the current operating temperature of PoE chip unit 1.
The unit 1 is in charge of PoE Port-1-Port-12
PoE Temperature Unit 2 Display the current operating temperature of PoE chip unit 2.
The unit 1 is in charge of PoE Port-13-Port-24
Over Temperature
Protection
Enable / Disable over temperature protection.
When the PoE temperature unit 1 / unit2 over 70 degree C then PoE
power budget will be changed by 3 segments as following.
Over 70 Degree C power budget 180 Watts
Over 73 Degree C power budget 170 Watts
Over 76 Degree C power budget 160 Watts
Power limit mode Allow you to configure the power limit mode of Web Smart Device. You
can choose :
Port Priority Deliver PoE power by port priority setting
Total Limit. Set limit value of the total POE port provided power to the
PDs.
Power Allocation Show the total watts usage of PoE Switch.
PoE Function Can enable or disable the PoE function.
Priority Set port priority for the POE power management
It can choose the “port priority”, value is :
Critical
High
Low
High priority is “Critical”.
Device class Class 0 is the default for PDs. However, to improve power management
at the PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the
maximum power that the PD will draw across all input voltages and
operational modes. A PD shall return Class 0 to 3 in accordance with
the maximum power draw as specified by Table 4.1.
Current(mA) It shows the PoE device current Amp.
Consumption [W] It shows the PoE device current watt.