GE GFK-0787B Noise Reduction Machine User Manual


 
5
5-21GFK-0787B Chapter 5 Diagnostics
Code MeaningMessage
10903 User_IF–Invalid Table Module was called with extended mode table number when the module was in nor-
mal mode
10903 Bad Table c (h) Module was called with an invalid table number (c=requested table in decimal,
h=requested table in hexadecimal)
10905 User_IF–Invalid Range Start or end address parameter is out of range for the specified table type
10906 User_IF–Table Space Destination parameter is out of range for the destination type of memory
10907 No fault contacts An attempt was made to read fault contact data, but no fault contacts were configured
10908 Bad blk loc r.s.b.d. An attempt was made to read an I/O shutdown timer for an invalid block Generated
by GMR_09.
10909 Bad GBC Loc r.s. An attempt was made to read all I/O shutdown timers for an invalid GBC. Generated
by GMR_09.
11001 Null GMR Configuration Configuration Module has detected a Null GMR configuration
11101 Unauthorized GMR Access GMR Configuration Module was invoked with incorrect password
11102 GMR S/W Except. %L %L parameter out of range
11201 Unauthorized GMR Access GMR Configuration Module was invoked with the incorrect password
11202 GMR S/W Except %L %L parameter out of range
11401 Unauthorized GMR Access GMR14 was invoked with the incorrect password
11402 Incorrect GMR Version GMR14 version does not match the GMR system version number
11403 GMR Software Exception Invalid call number was detected
11404 Invalid GMR Pointer The error code pointer was out of bounds
11410 GMR1–IS x at y GMR1 statemachine went to step x (illegal). Step no. at offset y in GMR1 diagnostics
11411 GMR1–ST x at y GMR1 state mach. exceeded allowed time in step x. Step no. at offset y in GMR1 diag-
nostics
11412 GMR1–IW x GMR1 has output an illegal waycode of x
11413 GMR1–tmplt too small GMR14 has detected an internal error condition
11415 GMR2–IS x at y GMR2 statemachine went to step x (illegal). Step no. at offset y in GMR2 diagnostics
11416 GMR2–ST x at y GMR2 state mach. exceeded allowed time in step x. Step no. at offset y in GMR2 diag-
nostics
11417 GMR2–IW x GMR2 has output an illegal waycode of x
11418 GMR2–tmplt too small GMR14 has detected an internal error condition
11420 GMR3–IS x at y GMR3 statemachine went to step x (illegal). Step no. at offset y in GMR3 diagnostics
11421 GMR3–ST x at y GMR3 state mach. exceeded allowed time in step x. Step no. at offset y in GMR3 diag-
nostics
11422 GMR3–IW x GMR3 has output an illegal waycode of x
11423 GMR3–tmplt too small GMR14 has detected an internal error condition
11430 GMR6–IS x at y GMR6 statemachine went to step x (illegal). Step no. at offset y in GMR6 diagnostics
11431 GMR6–ST x at y GMR6 state mach. exceeded allowed time in step x. Step no. at offset y in GMR6 diag-
nostics
11432 GMR6–IW x GMR6 has output an illegal waycode of x
11433 GMR6–tmplt too small GMR14 has detected an internal error condition
11440 GMR8–IS x at y GMR8 statemachine went to step x (illegal). Step no. at offset y in GMR8 diagnostics
11441 GMR8–ST x at y GMR8 state mach. exceeded allowed time in step x. Step no. at offset y in GMR8 diag-
nostics
11442 GMR8–IW x GMR8 has output an illegal waycode of x
11443 GMR8–tmplt too small GMR14 has detected an internal error condition
11445 GMR11–IS x at y GMR11 statemachine went to step x (illegal). Step no. at offset y in GMR11 diagnos-
tics
11446 GMR11–ST x at y GMR11 state mach. exceeded allowed time in step x. Step no. at offset y in GMR11 diag-
nostics
11447 GMR11–IW x GMR11 has output an illegal waycode of x
11448 GMR11–tmplt too small GMR14 has detected an internal error condition
11450 GMR12–IS x at y GMR12 statemachine went to step x (illegal). Step no. at offset y in GMR12 diagnos-
tics
11451 GMR12–ST x at y GMR12 state mach. exceeded allowed time in step x. Step no. at offset y in GMR12 diag-
nostics
11452 GMR12–IW x GMR12 has output an illegal waycode of x