Graco Inc. 224893 Surge Protector User Manual


 
Instructions–Parts List
308178F
ENG
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Dynamic Surge Suppressor
For use with double-diaphragm pumps and low-pressure reciprocating pumps.
For professional use only. Not for use in explosive atmospheres.
100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure
Model 224892, Series A
aluminum, with PTFE diaphragm
Model 224893, Series A
aluminum, with buna–N diaphragm
Model 224894, Series B
stainless steel, with PTFE diaphragm
Model 224895, Series B
stainless steel, with buna–N diaphragm
Table of Contents
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation and Maintenance 7. . . . . . . . . . . . . . . . . . .
Troubleshooting 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Drawing 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Lists 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repair Kits 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawing 15. . . . . . . . . . . . . . . . . . . . . . .
Technical Data 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number 20. . . . . . . . . . . . . . . . . . . . . . .
WARNING
Hazard of Using Fluids Containing Haloge-
nated Hydrocarbons
Never use 1.1.1–trichloroethane, methylene
chloride, other halogenated hydrocarbon solvents
or fluids containing such solvents in aluminum
models 224892 or 224893. Such use could result
in a chemical reaction, with the possibility of
explosion, which could cause death, serious bodily
injury, and/or substantial property damage.
Consult your fluid suppliers to ensure that the fluids
being used are compatible with aluminum and zinc
parts.
0903