HP (Hewlett-Packard) J8753A Network Router User Manual


 
61195890L1-13B, April 2005 www.procurve.com Copyright 2005 Hewlett-Packard Development Company, LP
Quick Start Guide 5991-2113
ProCurve Secure Router 7203dl
J8753A
INSTALL THE INTERFACE MODULE
1. Verify the unit is not connected to a power source.
2. (Optional) To install the backup module, carefully align the P1 connector on the interface
module with the J1 connector on the backup module. Using only fingertip pressure to
ensure that neither circuit board bends or flexes, firmly seat the connectors. Secure the
backup module to the interface module using the supplied screws and standoff posts.
3. Slide the interface module into the option slot until the module is firmly positioned
against the chassis.
4. Secure the screws at both edges of the module.
5. To install the wide module, align the module with the wide slot and slide the module into
the chassis until it is firmly positioned against the backplane connectors. Secure by
tightening the screws.
GROUND THE ROUTER
1. Strip one end of the ground wire to the length required for the ring terminal. (Ground wire
and ring terminal are supplied by the user. For more detailed grounding specifications,
please refer to the ProCurve Secure Router Installation Guide.)
2. Crimp the ground wire to the ring terminal, using a crimp tool of the appropriate size.
3. Attach the ring terminal to the chassis as shown in the figure to the right.
4. Connect the other end of the ground wire to a suitable grounding point at your site.
5. Apply power to the unit.
Note
For information on installing the Encryption and Compact Flash modules
please refer to the ProCurve Secure Router Installation Guide included in
your router shipment.
CONNECT TO THE PROCURVE SECURE ROUTER 7203DL CONSOLE
Before connecting to the ProCurve Secure Router 7203dl Console interface you will need the
following items: VT100 terminal or PC (with VT100 terminal emulation software) and the serial
cable (5184-1894) supplied with your router. (This is the same console cable used in other
ProCurve switches such as the 5300xl series.)
1. Connect the DB-9 (female) connector of your cable to the DB-9 DTE (male) Console
interface on the front panel of the unit.
2. Connect the loose end of the cable to the VT100 terminal or PC (with terminal emulation
software).
3. Open a VT100 terminal session to the ProCurve Secure Router 7203dl using the
following settings: 9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to
activate the HP Command Line Interface.
4. Enter enable at the > prompt.
5. Enter the password when prompted or press <Enter> if you have not yet set a
password.
Console
Power
Fault
Eth 0/1
Eth 0/2
Stat Stat
Slots
12
Bkp Bkp
Tx Tx
Rx Rx
Stat
3
Act
Test
dl dl
ProCurve 7203dl
Secure Router
J8753A
dl
wide