Hitachi 1000 Personal Computer User Manual


 
www.hitachi.com BladeSymphony 1000 Architecture White Paper 37
Module Connections
Chassis A can have up to eight server blades mounted, with two PCI-X slots per server blade. Storage
modules cannot be mounted on these chassis.
Chassis B can have three types of I/O modules mounted. If a PCI-X I/O Module is installed, the chassis
can have up to four server blades with four PCI-X slots connected to each server blade, and up to four
storage modules or server blades with no PCI-X connection. If a PCIe I/O Module is installed, the
chassis can have up to eight server blades, with up to two PCIe slots per server blade. If a Embedded
Fibre Channel Switch Module is installed, the chassis can have up to eight server blades, with up to two
Fibre Channel ports and two gigabit Ethernet ports connected per server blade.
Redundant Power Modules
The Power Module includes a 200-240 VAC input, and supplies the sub- and main-power to the
system. Up to four Power Modules are installable in a chassis. They are installed redundantly, and
support hot swapping. The service processor (SVP) checks the power capacity when it starts up.
If SVD detects redundant power capacity, it boots the system in the normal way. If SVP cannot detect
Switch & Management Module 1 standard, 2 maximum 1 standard, 2 maximum
I/O Module (PCI-X) 2 maximum
2 slots maximum per server
blade, 16 slots maximum per
server chassis
2 maximum
4 slots maximum per server
blade, 16 slots maximum
per server chassis
I/O Module (PCIe) N/A 2 maximum
2 slots maximum per server
blade, 16 slots maximum
per server chassis
I/O Module (Fibre Channel Switch) N/A 2 Maximum
Power Module 4 maximum (N+1 redundant configuration)
Cooling Fan Module 4 standard (3+1 redundant configuration)
USB CD-ROM Drive Optional
USB Floppy Disk Drive Optional
Outside Dimension 17.5 x 33.5 x 17.4 inches/ 10 RU
Weight 308 pounds (lbs)
Input Voltage (frequency) 200-240 VAC, single phase (50/60 Hz)
Power Consumption (maximum) 4.5 kW
Operating Temperature 41 to 55 degrees Fahrenheit
Humidity (no condensation) 20 to 80 percent
Module Type A Type B