Honeywell 1902 Scanner User Manual


 
4 - 7
ble scan speed but slightly less range than Normal mode. Enhanced mode
is best used when you require a very fast scan speed and don’t require a
long working range.
Serial Trigger
You can activate the scanner either by pressing the trigger, or using a serial
trigger command (see Trigger Commands on page 11-4). When in serial
mode, the scanner scans until a bar code has been read or until the deacti-
vate command is sent. The scanner can also be set to turn itself off after a
specified time has elapsed (see Read Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s
trigger when using serial commands to trigger the scanner. Once the
scanner has timed out, you can activate the scanner either by pressing
the trigger or using a serial trigger command. After scanning the Read
Time-Out bar code, set the time-out duration (from 0-300,000 millisec-
onds) by scanning digits on the Programming Chart inside the back
cover, then scanning Save.
Default = 30,000 ms.
Scanner Power Time-Out Timer
Note: Scanner Power Time-out Timer only applies to cordless systems.
It does not apply to corded scanners.
When there is no activity within a specified time period, the scanner
enters low power mode. Scan the appropriate scanner power time-out
bar code to change the time-out duration (in seconds).
Note: Scanning zero (0) is the equivalent of setting no time-out.
* Manual Trigger - Normal
Manual Trigger - Enhanced
Read Time-Out