Honeywell 2700 Scanner User Manual


 
14 - 1
14
Product Specifications
Stratos Bioptic Scanner/Scale Product Specifications
Parameter Specification
Model 2753 Dimensions (Typical):
Height
11.1 inches (28.2cm)
Length
20 inches (50.8cm)
Width
11.5 inches (7.1cm)
Weight:
Without Scale
With Scale
17.85 lbs. (8.1kg)
23.85 lbs. (10.8kg)
Model 2752 Dimensions (Typical):
Height
11.1 inches (28.2cm)
Length
15.7 inches (39.9cm)
Width
11.5 inches (7.1cm)
Weight:
Without Scale
With Scale
16.55 lbs. (7.5kg)
21.8 lbs. (9.9kg)
Model 2751 Dimensions (Typical):
Height
11.1 inches (28.2cm)
Length
13.9 inches (35.3cm)
Width
11.5 inches (7.11cm)
Weight:
Without Scale
15.75 lbs. (7.1kg)
Optical
Laser Scan Lines
21,500 per second
Imager Resolution
838 x 640 pixel array
LED
635nm + 40nm (red LED)
IEC 62471: “Exempt Risk Group”
Operating Wavelength
Illumination
650nm + 5nm
Laser
650nm
Voltage Requirements 12V +
10%
Current Draw 12VDC @ 25°C Operating Standby
Stratos bioptic scanner only
.85A .41A
Stratos bioptic scanner with LCD Video display
.93A .41A
Stratos bioptic with LCD Video display, and scale with
single line display
1A .47A
Maximum Auxiliary Power
12V video port
.3A
Other aux ports
.5A
Temperature Ranges:
Operating
+50F to +104F (10C to 40C)
Storage
-40F to +158F (-40C to 70C)
Humidity 5% - 95% relative humidity, non-condensing
ESD Immunity IEC 61000-4-2 (8kV contact / 15kV air)
Safety/Compliance
Laser
IEC Class 1
LED