name4
The name of a 4-byte area that is to receive the length, in bytes, of the
TWA.
(Rn) A register that is to receive the length of the TWA.
* The parameter list itself, name APIQ_TWASIZE, is used to hold the
length of the TWA.
RESPONSE and REASON values for INQ_APPLICATION_DATA:
RESPONSE REASON
OK None
EXCEPTION DPL_PROGRAM
NO_TRANSACTION_ENVIRONMENT
TRANSACTION_DOMAIN_ERROR
DISASTER ABEND
LOOP
INQ_FAILED
INVALID INVALID_FUNCTION
KERNERROR None
PURGED None
The INQUIRE_SYSTEM call
The INQUIRE_SYSTEM call gives you access to CICS system data in the AP
domain.
INQUIRE_SYSTEM
DFHSAIQX [CALL,]
[CLEAR,]
[IN,
FUNCTION(INQUIRE_SYSTEM),
[GMMTEXT(name4),]]
[OUT,
[CICSREL(name4 | *),]
[CICSSTATUS(ACTIVE | FINALQUIESCE |
FIRSTQUIESCE| INITIALIZING),]
[CICSSYS(name1 | *),]
[CICTSLEVEL(name6 | *),]
[CWA(name4 | (Rn) | *),]
[CWALENGTH(name2 | *),]
[DATE(name4|*),]
[DTRPRGRM(name8 | *),]
[GMMLENGTH(name2 | *),]
[GMMTRANID(name4 | *),]
[INITSTATUS(FIRSTINIT | INITCOMPLETE | SECONDINIT |
THIRDINIT),]
[JOBNAME(name8 | *),]
[OPREL(name2 | *),]
[OPSYS(name1 | *),]
[OSLEVEL(name4 | *),]
[PLTPI(name2 | *),]
[SDTRAN(name4 | *),]
[SECURITYMGR(EXTSECURITY | NOSECURITY),]
[SHUTSTATUS(CONTROLSHUT | NOTSHUTDOWN | SHUTDOWN),]
[STARTUP(COLDSTART | EMERGENCY | WARMSTART),]
[STARTUPDATE(name4| *),]
[TERMURM(name8 | *),]
386 Customization Guide