Note: The Hardware contained within package option will not be valid for a remote
system unit since no packages for hardware within them will be created.
This is because HRI will not see VPD from any resources within a remote
system unit or remote expansion unit.
Selecting the Display SPCN system information function key will cause the following
display to appear. This display lists the System Power Control Network (SPCN)
type and serial number. The SPCN type and serial number is the type and serial
number of the system that controls the power for this resource.
Packaging Hardware Resources
Local system type....: 9406
Local system serial number: 10-0033333
Type options, press Enter.
2=Change detail 3=Concurrent maintenance 4=Remove 5=Display detail
8=Associated logical resource(s) 9=Hardware contained within package
Opt Description Type-Model Frame ID Resource Name
_ System 9406-500 SYS01
_ System Unit + 9406-500 1 FR01
_ System Expansion Unit + 5073-001 2 FR02F
_ Rack Enclosure 9309-002 22 FR03F
_ Rack Enclosure + 9309-002 23 FR04F
_ Remote System 9406-730 SYS03S
_ Remote System Unit 9406-730 1 FR05S
_ Remote Expansion Unit + 5083-001 2 FR06F
F3=Exit F5=Refresh F6=Print F8=Exclude non-reporting resources
F9=Reserve frame space F10=Non-reporting resources
F11=Display SPCN system information F12=Cancel F13=Unresolved locations
Figure 6. Example Packaging Hardware Resources display
48 Service Functions V5R2