IBM xSeries 330 Server User Manual


 
Chapter 7. Symptom-to-FRU index 93
0001200 (Machine check architecture
error)
1. Processor 1
2. Optional Processor 2
3. System Board.
1600 (The Service Processor is not
functioning) Do the following before
replacing a FRU:
1. Do the following before replacing a FRU:
a. Ensure that a jumper is not installed on J28.
b. Remove the ac power to the system, wait 20 seconds; then, re-
connect the ac power. Wait 30 seconds; then, power-on the
system.
2. System Board
1601 (The system is able to
communicate to the Service Processor, but
the Service Processor failed to respond at
the start of POST.)
1. Do the following before replacing a FRU:
a. Remove the ac power to the system, wait 20 seconds; then, re-
connect the ac power. Wait 30 seconds; then, power-on the
system.
b. Flash update the Service Processor.
2. System Board
1762 (Fixed Disk Configuration error)
(IDE drive only)
1. Fixed Disk Drive
2. Fixed Disk Cables
3. Run Configuration/Setup
4. System Board
178X (Fixed Disk error) (IDE drive
only)
1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Drive
4. System Board
1800 (No more hardware interrupt
available for PCI adapter)
1. Run Configuration/Setup
2. Remove Adapter
1801 (no more ROM space available for
PCI adapter)
1. Run Configuration/Setup
2. Remove adapter
3. Disable adapter BIOS on adapter and run Configuration/Setup
1962 (Drive does not contain a valid
boot sector)
1. Verify a bootable operating system is installed.
2. Run Diagnostics
3. Hard Disk Drive
4. SCSI Backplane
5. Cable
6. System Board
2400 (Video controller test failure) 1. Video Adapter (if installed)
2. System Board
2462 (Video memory configuration
error)
1. Video Adapter (if installed)
2. System Board
Error Code/Symptom FRU/Action