Intel X18-M Computer Drive User Manual


 
Intel
®
X18-M/X25-M SATA Solid State Drive
February 2009 Product Manual
Order Number: 319765-006US 9
Intel
®
X18-M/X25-M SATA SSD
3.4 Environmental Conditions
3.4.1 Temperature
Note: Measured without condensation.
3.4.2 Altitude
The drive is not sensitive to changes in altitude because it has no moving parts. Drive
tested within -1K and +40K feet.
3.4.3 Shock and Vibration
Notes:
1. Shock specifications assumes that the SSD is mounted securely with the input vibration applied to the drive mounting
screws. Stimulus may be applied in the X, Y or Z axis.
2. Vibration specifications assumes that the SSD is mounted securely with the input vibration applied to the drive mounting
screws. Stimulus may be applied in the X, Y or Z axis.
3. Sine wave sweeping 1 oct/min.
3.4.4 Acoustics
The SSD has no moving or noise-emitting parts; therefore, it produces negligible sound
(0 dB) in all modes of operation.
Table 9. Temperature Related Specifications
Mode Min Typ Max Unit
Ambient Temperature
Operating 0 70
o
C
Non-Operating -55 95
o
C
Temperature Gradient
Operating 20
o
C/hr *
Non-Operating 30
o
C/hr *
Humidity
Operating 5 95 %
Non-Operating 5 95 %
Table 10. Shock and Vibration Specifications
Mode Timing Max Unit
Shock
1
Operating at 0.5 msec 1,000 G
Non-Operating at 0.5 msec 1,000 G
Vibration
2
Operating 2.17 G 7-800 Hz
Non-Operating 3.13 G 10-500 Hz
3