Lenovo 4088 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 1. Check fans
2. Check Power supply voltages
3. Microprocessor
4. System board
185-000-XXX Asset Security Test Passed
No action
185-XXX-XXX Asset Security failure
1. Flash system
2. System board
185-278-XXX Asset Security Chassis Intrusion 1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX System Memory Test Passed
No action
201-XXX-XXX System Memory error
1. Replace the memory module called out by the test
2. System board
202-000-XXX System Cache Test Passed
No action
202-XXX-XXX System Cache error 1. Cache, if removable
2. System board
3. Microprocessor
206-000-XXX Diskette Drive Test Passed No action
206-XXX-XXX Diskette Drive error
1. Diskette Drive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
215-000-XXX CD-ROM Drive Test Passed
No action
215-XXX-XXX CD-ROM Drive error 1. CD-ROM Drive Cable
2. Check power supply voltages
3. CD-ROM drive
4. System board
217-000-XXX Hard Disk Drive Test Passed No action
217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error 1. Hard Disk Drive Cable
2. Check power supply voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (IDE)
5. System board
217-28X-XXX 217-29X-XXX Hard Disk Drive (SCSI) error 1. Hard Disk Drive Cable
2. Check power supply voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (SCSI)
5. SCSI adapter card
6. System board
220-000-XXX Hi-Capacity Cartridge Drive Test Passed
No action
64 ThinkCentre Hardware Maintenance Manual