Lenovo 5068 Personal Computer User Manual


 
Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page
50 for the specic type for information about the diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX BIOS Test Passed
No action
000-002-XXX BIOS Timeout 1. Flash the system. See “Flash update procedures”
on page 151
.
2. System board
000-024-XXX BIOS Addressing test failure 1. Flash the system. See “Flash update procedures”
on page 151
.
2. System board
000-025-XXX BIOS Checksum Value error 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
000-026-XXX FLASH data error 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
000-027-XXX BIOS Conguration/Setup error 1. Run the Setup Utility program.
2. Flash the system. See “Flash update procedures”
on page 151.
3. System board
000-034-XXX BIOS Buffer Allocation failure
1. Reboot the system.
2. Flash the system. See “Flash update procedures”
on page 151.
3. Run memory test
4. System board
000-035-XXX BIOS Reset Condition detected 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
000-036-XXX BIOS Register error 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
000-038-XXX BIOS Extension failure 1. Flash the system. See “Flash update procedures”
on page 151
.
2. Adapter card
3. System board
000-039-XXX BIOS DMI data error 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
000-195-XXX BIOS Test aborted by user
Information only Restart the test, if necessary
000-196-XXX BIOS test halt, error threshold exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
58 ThinkCentre Edge Hardware Maintenance Manual