Diagnostic Error Code FRU/Action
011-196-XXX Serial port test halt, error threshold exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
011-197-XXX Serial port test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53
.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
011-198-XXX Serial port test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53
.
2. Flash the system and re-test. See “Flash update
procedures” on page 151.
3. Go to “Undetermined problems” on page 78.
011-199-XXX Serial port test failed, cause unknown 1. Go to “Undetermined problems” on page 78.
2. Flash the system and re-test. See “Flash update
procedures” on page 151.
3. Replace component under function test.
011-2XX-XXX Serial port signal failure
1. External serial device
2. System board
014-000-XXX Parallel port Interface Test Passed
No action
014-001-XXX Parallel port Presence
1. Remove external parallel device, if present.
2. Run the Setup Utility program, enable port
3. System board
014-002-XXX 014-003-XXX Parallel port Timeout/Parity
error
System board
014-013-XXX 014-014-XXX Parallel port Control
Signal/Loopback test failure
System board
014-015-XXX Parallel port External Loopback failure
1. Wrap plug
2. System board
014-027-XXX Parallel port Conguration/Setup error 1. Run the Setup Utility program, enable port
2. Flash the system. See “Flash update procedures”
on page 151.
3. System board
014-03X-XXX 014-04X-XXX Parallel port failure
System board
014-195-XXX Parallel port Test aborted by user
Information only Restart the test, if necessary.
014-196-XXX Parallel port test halt, error threshold
exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
64 ThinkCentre Edge Hardware Maintenance Manual