Diagnostic Error Code FRU/Action
014-197-XXX Parallel port test warning 1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53
.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
014-198-XXX Parallel port test aborted
1. If a component is called out, make sure it is
connected and/or enabled.
2. Flash the system and re-test. See “Flash update
procedures” on page 151.
3. Go to “Undetermined problems” on page 78.
014-199-XXX Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page 78.
2. Flash the system and re-test. See “Flash update
procedures” on page 151
.
3. Replace component under function test.
014-2XX-XXX 014-3XX-XXX Parallel port failure
1. External parallel device
2. System board
015-000-XXX USB port Interface Test Passed
No action
015-001-XXX USB port Presence 1. Remove USB device(s) and re-test.
2. System board
015-002-XXX USB port Timeout 1. Remove USB device(s) and re-test.
2. System board
015-015-XXX USB port External Loopback failure 1. Remove USB device(s) and re-test.
2. System board
015-027-XXX USB port Conguration/Setup error 1. Flash the system. See “Flash update procedures”
on page 151.
2. System board
015-032-XXX USB port Device Controller failure System board
015-034-XXX USB port buffer allocation failure
1. Reboot the system
2. Flash the system and re-test. See “Flash update
procedures” on page 151.
3. Run memory test.
4. System board
015-035-XXX USB port Reset condition detected 1. Remove USB device(s) and re-test.
2. System board
015-036-XXX USB port Register error System board
015-040-XXX USB port IRQ failure 1. Run the Setup Utility program and check for
conicts.
2. Flash the system. See “Flash update procedures”
on page 151.
3. System board
015-195-XXX USB port Test aborted by user
Information only Restart the test, if necessary.
Chapter 7. Symptom-to-FRU Index 65