Symptom or error FRU or action, in sequence
2010
Warning: Your internal hard disk drive
(HDD) may not function correctly on this
system. Ensure that your HDD is supported
on this system and that the latest HDD
firmware is installed.
Inform the following information to the
customer:
If in the primary bay the customer is using a
non-IBM or non-Lenovo hard disk drive
(HDD), or an old generation IBM HDD
which is not supported by this system, with
the risk in mind, the customer can still use it
by pressing ESC. If in the primary drive bay
the customer is using a supported
IBM/Lenovo HDD with an old firmware,
the customer needs to update its firmware to
the latest. The latest version is available at
http://www.lenovo.com/support
2100
Initialization error on HDD0 (Main hard
disk drive)
1. Reseat the hard disk drive.
2. Main hard disk drive.
3. System board.
2102
Initialization error on HDD1 (Ultrabay hard
disk drive)
1. Reseat the hard disk drive.
2. Ultrabay hard disk drive.
3. System board.
2110
Read error on HDD0 (Main hard disk drive)
1. Reseat the hard disk drive.
2. Main hard disk drive.
3. System board.
2112
Read error on HDD1 (Ultrabay hard disk
drive)
1. Reseat the hard disk drive.
2. Ultrabay hard disk drive.
3. System board.
Error messages
Symptom or error FRU or action, in sequence
Device address conflict. 1. Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Allocation error for device. 1. Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Failing bits: nnnn. 1. DIMM.
2. System board.
Invalid system configuration data. 1. DIMM.
2. System board.
I/O device IRQ conflict. 1. Load “Setup Defaults” in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
Hibernation error. 1. Restore the system configuration to
what it was before the computer
entered hibernation mode.
2. If memory size has been changed,
re-create the hibernation file.
Symptom-to-FRU index
ThinkPad X60, X60s, X61, and X61s 51